CVE-2019-8268 (GCVE-0-2019-8268)
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-17 01:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-193 - Off-by-one Error
Summary
UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.
References
► | URL | Tags | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Kaspersky Lab | UltraVNC |
Version: 1.2.2.3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.455Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-193", "description": "CWE-193: Off-by-one Error", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:52:16", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8268", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-193: Off-by-one Error" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8268", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-17T01:16:16.319Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-8268\",\"sourceIdentifier\":\"vulnerability@kaspersky.com\",\"published\":\"2019-03-08T23:29:00.623\",\"lastModified\":\"2024-11-21T04:49:36.873\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.\"},{\"lang\":\"es\",\"value\":\"UltraVNC, en su revisi\u00f3n 1206, tiene m\u00faltiples vulnerabilidades de error por un paso en el c\u00f3digo del cliente VNC conectadas con el uso incorrecto de la funci\u00f3n ClientConnection::ReadString, lo cual puede resultar, potencialmente, en la ejecuci\u00f3n de c\u00f3digo. Este ataque parece ser explotable mediante la conectividad de red. Se han solucionado estas vulnerabilidades en la revisi\u00f3n 1207.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"vulnerability@kaspersky.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-193\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-193\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.2.2.3\",\"matchCriteriaId\":\"555D034F-3D64-4ED1-9B63-F8D59199E99C\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_access_mymachine\\\\/p2p:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.8\",\"matchCriteriaId\":\"D9345335-DF62-4472-93CD-E2C85453F91E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_pcu_base_win10_software\\\\/ipc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"14.00\",\"matchCriteriaId\":\"7498412D-79FD-43FE-AD9B-5820FB5CF7D8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_pcu_base_win7_software\\\\/ipc:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"12.01\",\"matchCriteriaId\":\"1F603341-03C5-46CA-8A74-EC5A50135194\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\",\"source\":\"vulnerability@kaspersky.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/\",\"source\":\"vulnerability@kaspersky.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\",\"source\":\"vulnerability@kaspersky.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…