CVE-2020-10611 (GCVE-0-2020-10611)
Vulnerability from cvelistv5
Published
2020-04-15 18:36
Modified
2024-08-04 11:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-843 - ACCESS OF RESOURCE USING INCOMPATIBLE TYPE ('TYPE CONFUSION')
Summary
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
References
► | URL | Tags | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 |
Version: Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:06:10.007Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-549/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122" } ] } ], "descriptions": [ { "lang": "en", "value": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-843", "description": "ACCESS OF RESOURCE USING INCOMPATIBLE TYPE (\u0027TYPE CONFUSION\u0027) CWE-843", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T18:06:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-549/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-10611", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122", "version": { "version_data": [ { "version_value": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "ACCESS OF RESOURCE USING INCOMPATIBLE TYPE (\u0027TYPE CONFUSION\u0027) CWE-843" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-549/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-549/" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-10611", "datePublished": "2020-04-15T18:36:16", "dateReserved": "2020-03-16T00:00:00", "dateUpdated": "2024-08-04T11:06:10.007Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-10611\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-04-15T19:15:13.613\",\"lastModified\":\"2024-11-21T04:55:41.810\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.\"},{\"lang\":\"es\",\"value\":\"Triangle MicroWorks SCADA Data Gateway versiones 3.02.0697 hasta 4.0.122, versiones 2.41.0213 hasta 4.0.122, permite a atacantes remotos ejecutar c\u00f3digo arbitrario debido a la falta de comprobaci\u00f3n apropiada de los datos suministrados por el usuario, lo que puede causar una condici\u00f3n de confusi\u00f3n de tipos. No es requerida una autenticaci\u00f3n para explotar esta vulnerabilidad. Solo aplicable a instalaciones que utilizan DNP3 Data Sets.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-843\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-843\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.41.0213\",\"versionEndIncluding\":\"4.0.122\",\"matchCriteriaId\":\"3F22582F-32D4-4E3A-AF76-CDB180CC0D03\"}]}]}],\"references\":[{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-105-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-20-549/\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-105-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-20-549/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…