Summary
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:25:49.053Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Nexpose", "vendor": "Rapid7", "versions": [ { "lessThan": "6.6.40", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "This issue was discovered and reported by Mishra Dhiraj. " } ], "descriptions": [ { "lang": "en", "value": "In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-09-03T13:55:25", "orgId": "9974b330-7714-4307-a722-5648477acda7", "shortName": "rapid7" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40" } ], "source": { "discovery": "UNKNOWN" }, "title": "Code Injection in Rapid7 Nexpose Installer", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@rapid7.com", "ID": "CVE-2020-7381", "STATE": "PUBLIC", "TITLE": "Code Injection in Rapid7 Nexpose Installer" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Nexpose", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "6.6.40" } ] } } ] }, "vendor_name": "Rapid7" } ] } }, "credit": [ { "lang": "eng", "value": "This issue was discovered and reported by Mishra Dhiraj. " } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40", "refsource": "MISC", "url": "https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7", "assignerShortName": "rapid7", "cveId": "CVE-2020-7381", "datePublished": "2020-09-03T13:55:25", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:25:49.053Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-7381\",\"sourceIdentifier\":\"cve@rapid7.com\",\"published\":\"2020-09-03T14:15:10.977\",\"lastModified\":\"2024-11-21T05:37:08.257\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.\"},{\"lang\":\"es\",\"value\":\"En el instalador de Rapid7 Nexpose versiones anteriores a 6.6.40, el instalador de Nexpose llama un ejecutable que puede ser colocado por un atacante en el directorio apropiado con acceso a la m\u00e1quina local.\u0026#xa0;Esto impedir\u00eda que el instalador distinga entre un ejecutable v\u00e1lido llamado durante una instalaci\u00f3n de Security Console y cualquier c\u00f3digo arbitrario ejecutable usando el mismo nombre de archivo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L\",\"baseScore\":5.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.3,\"impactScore\":5.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rapid7:nexpose:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.6.40\",\"matchCriteriaId\":\"C3F6D1B0-EBA8-49AF-85E7-5D38810610F3\"}]}]}],\"references\":[{\"url\":\"https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40\",\"source\":\"cve@rapid7.com\",\"tags\":[\"Release Notes\",\"Vendor Advisory\"]},{\"url\":\"https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Release Notes\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…