CVE-2021-21580 (GCVE-0-2021-21580)
Vulnerability from cvelistv5
Published
2021-08-03 15:30
Modified
2024-09-16 17:33
CWE
  • CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Summary
Dell EMC iDRAC8 versions prior to 2.80.80.80 & Dell EMC iDRAC9 versions prior to 5.00.00.00 contain a Content spoofing / Text injection, where a malicious URL can inject text to present a customized message on the application that can phish users into believing that the message is legitimate.
Impacted products
Vendor Product Version
Dell Integrated Dell Remote Access Controller (iDRAC) Version: unspecified   < 5.00.00.00
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.446Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189193"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Integrated Dell Remote Access Controller (iDRAC)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.00.00.00",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-06-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC iDRAC8 versions prior to 2.80.80.80 \u0026 Dell EMC iDRAC9 versions prior to 5.00.00.00 contain a Content spoofing / Text injection, where a malicious URL can inject text to present a customized message on the application that can phish users into believing that the message is legitimate."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-03T15:30:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189193"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-06-30",
          "ID": "CVE-2021-21580",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Integrated Dell Remote Access Controller (iDRAC)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.00.00.00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC iDRAC8 versions prior to 2.80.80.80 \u0026 Dell EMC iDRAC9 versions prior to 5.00.00.00 contain a Content spoofing / Text injection, where a malicious URL can inject text to present a customized message on the application that can phish users into believing that the message is legitimate."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 4.3,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189193",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189193"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21580",
    "datePublished": "2021-08-03T15:30:23.368761Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-16T17:33:01.755Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-21580\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2021-08-03T16:15:08.213\",\"lastModified\":\"2024-11-21T05:48:38.763\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC iDRAC8 versions prior to 2.80.80.80 \u0026 Dell EMC iDRAC9 versions prior to 5.00.00.00 contain a Content spoofing / Text injection, where a malicious URL can inject text to present a customized message on the application that can phish users into believing that the message is legitimate.\"},{\"lang\":\"es\",\"value\":\"Dell EMC iDRAC8  versiones anteriores a 2.80.80.80 y Dell EMC iDRAC9 versiones anteriores a 5.00.00.00, contienen una falsificaci\u00f3n de Contenido e Inyecci\u00f3n de Texto, donde una URL maliciosa puede inyectar texto para presentar un mensaje personalizado en la aplicaci\u00f3n que puede hacer creer a usuarios que el mensaje es leg\u00edtimo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-74\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-74\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_idrac8_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.80.80.80\",\"matchCriteriaId\":\"7F41D946-F55F-4522-8BD7-D15DDEC4213A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_idrac9_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.00.00.00\",\"matchCriteriaId\":\"CA408D1B-7586-48E9-9545-149C53B55B05\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/000189193\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/000189193\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…