CVE-2021-23196 (GCVE-0-2021-23196)
Vulnerability from cvelistv5
Published
2022-01-21 18:17
Modified
2025-04-16 16:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-522 - Insufficiently Protected Credentials
Summary
The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Fresenius Kabi | Agilia Link+ |
Version: unspecified < 3.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:05:55.666Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2021-23196", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-04-16T16:00:02.890579Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-16T16:47:57.851Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Agilia Link+", "vendor": "Fresenius Kabi", "versions": [ { "lessThan": "3.0", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project)." } ], "descriptions": [ { "lang": "en", "value": "The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "CWE-522 Insufficiently Protected Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-21T18:17:36.000Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01" } ], "solutions": [ { "lang": "en", "value": "Fresenius Kabi has created new versions to address these vulnerabilities:\n\u2022\tLink+ v3.0 (D16 or later)\n\u2022\tVSS v1.0.3 (or later)\n\u2022\tAgilia Connect Pumps Wifi Module (D29 or later)\n\u2022\tAgilia Connect Partner v3.3.2 (or later) \nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \n" } ], "source": { "advisory": "ICSMA-21-355-01", "discovery": "EXTERNAL" }, "title": "Fresenius Kabi Agilia Connect Infusion System insufficiently protected credentials", "workarounds": [ { "lang": "en", "value": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\u2022\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\n\u2022\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\n\u2022\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n" } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-23196", "STATE": "PUBLIC", "TITLE": "Fresenius Kabi Agilia Connect Infusion System insufficiently protected credentials" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Agilia Link+", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "3.0" } ] } } ] }, "vendor_name": "Fresenius Kabi" } ] } }, "credit": [ { "lang": "eng", "value": "Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project)." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-522 Insufficiently Protected Credentials" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01" } ] }, "solution": [ { "lang": "en", "value": "Fresenius Kabi has created new versions to address these vulnerabilities:\n\u2022\tLink+ v3.0 (D16 or later)\n\u2022\tVSS v1.0.3 (or later)\n\u2022\tAgilia Connect Pumps Wifi Module (D29 or later)\n\u2022\tAgilia Connect Partner v3.3.2 (or later) \nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \n" } ], "source": { "advisory": "ICSMA-21-355-01", "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\u2022\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\n\u2022\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\n\u2022\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n" } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-23196", "datePublished": "2022-01-21T18:17:36.000Z", "dateReserved": "2021-11-30T00:00:00.000Z", "dateUpdated": "2025-04-16T16:47:57.851Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-23196\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-01-21T19:15:08.010\",\"lastModified\":\"2024-11-21T05:51:21.517\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently.\"},{\"lang\":\"es\",\"value\":\"La aplicaci\u00f3n web en Agilia Link+ versi\u00f3n 3.0 implementa los mecanismos de autenticaci\u00f3n y gesti\u00f3n de sesiones exclusivamente en el lado del cliente y no protege suficientemente los atributos de autenticaci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-522\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fresenius-kabi:agilia_connect_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"d25\",\"matchCriteriaId\":\"8B4979F9-A7D5-4B5C-8FF2-C3C67773EE03\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fresenius-kabi:agilia_connect:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D1BBB63E-7E43-4BC1-A08F-4F1F811F839B\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fresenius-kabi:agilia_partner_maintenance_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.3.0\",\"matchCriteriaId\":\"3B072164-6AA2-4A14-B7D7-10B4B953004D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fresenius-kabi:vigilant_centerium:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C47210A7-4753-4ED7-8E6B-9BE8EBFABC9F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fresenius-kabi:vigilant_insight:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C91B931-F726-4AB2-B3A6-D92F774CF04D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fresenius-kabi:vigilant_mastermed:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"04AC7167-F5C8-46A2-B937-953E13D76A32\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fresenius-kabi:link\\\\+_agilia_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"45FA28DE-939F-4146-A6E2-CE8849C9CB16\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fresenius-kabi:link\\\\+_agilia_firmware:3.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D5FC3D0-9593-487B-B70A-F8BBCA8A18FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fresenius-kabi:link\\\\+_agilia_firmware:3.0:d15:*:*:*:*:*:*\",\"matchCriteriaId\":\"67E88F2E-C12B-4B50-B087-3247F4748AF3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fresenius-kabi:link\\\\+_agilia:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1548AA3F-659F-43C3-9261-C7FD55465877\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T19:05:55.666Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2021-23196\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T16:00:02.890579Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T16:00:04.531Z\"}}], \"cna\": {\"title\": \"Fresenius Kabi Agilia Connect Infusion System insufficiently protected credentials\", \"source\": {\"advisory\": \"ICSMA-21-355-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project).\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Fresenius Kabi\", \"product\": \"Agilia Link+\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"lessThan\": \"3.0\", \"versionType\": \"custom\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Fresenius Kabi has created new versions to address these vulnerabilities:\\n\\u2022\\tLink+ v3.0 (D16 or later)\\n\\u2022\\tVSS v1.0.3 (or later)\\n\\u2022\\tAgilia Connect Pumps Wifi Module (D29 or later)\\n\\u2022\\tAgilia Connect Partner v3.3.2 (or later) \\nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \\n\"}], \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\", \"tags\": [\"x_refsource_MISC\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\\n\\u2022\\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\\n\\u2022\\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\\n\\u2022\\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\\n\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-522\", \"description\": \"CWE-522 Insufficiently Protected Credentials\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-01-21T18:17:36.000Z\"}, \"x_legacyV4Record\": {\"credit\": [{\"lang\": \"eng\", \"value\": \"Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project).\"}], \"impact\": {\"cvss\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}}, \"source\": {\"advisory\": \"ICSMA-21-355-01\", \"discovery\": \"EXTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"3.0\", \"version_affected\": \"\u003c\"}]}, \"product_name\": \"Agilia Link+\"}]}, \"vendor_name\": \"Fresenius Kabi\"}]}}, \"solution\": [{\"lang\": \"en\", \"value\": \"Fresenius Kabi has created new versions to address these vulnerabilities:\\n\\u2022\\tLink+ v3.0 (D16 or later)\\n\\u2022\\tVSS v1.0.3 (or later)\\n\\u2022\\tAgilia Connect Pumps Wifi Module (D29 or later)\\n\\u2022\\tAgilia Connect Partner v3.3.2 (or later) \\nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \\n\"}], \"data_type\": \"CVE\", \"generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"references\": {\"reference_data\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\", \"name\": \"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-522 Insufficiently Protected Credentials\"}]}]}, \"work_around\": [{\"lang\": \"en\", \"value\": \"CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\\n\\u2022\\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\\n\\u2022\\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\\n\\u2022\\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\\n\"}], \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2021-23196\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Fresenius Kabi Agilia Connect Infusion System insufficiently protected credentials\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\"}}}}", "cveMetadata": "{\"cveId\": \"CVE-2021-23196\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-16T16:47:57.851Z\", \"dateReserved\": \"2021-11-30T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2022-01-21T18:17:36.000Z\", \"assignerShortName\": \"icscert\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…