CVE-2021-27660 (GCVE-0-2021-27660)
Vulnerability from cvelistv5
Published
2021-07-01 13:36
Modified
2024-09-16 19:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - Improper Input Validation
Summary
An insecure client auto update feature in C-CURE 9000 can allow remote execution of lower privileged Windows programs.
References
► | URL | Tags | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Johnson Controls | C-CURE 9000 |
Version: All versions of C-CURE 9000 prior to 2.80 < 2.80 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:26:10.691Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories" }, { "name": "ICS-CERT Advisory", "tags": [ "third-party-advisory", "x_refsource_CERT", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "C-CURE 9000", "vendor": "Johnson Controls", "versions": [ { "lessThan": "2.80", "status": "affected", "version": "All versions of C-CURE 9000 prior to 2.80", "versionType": "custom" } ] } ], "datePublic": "2021-07-01T00:00:00", "descriptions": [ { "lang": "en", "value": "An insecure client auto update feature in C-CURE 9000 can allow remote execution of lower privileged Windows programs." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-02T10:12:24", "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01", "shortName": "jci" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories" }, { "name": "ICS-CERT Advisory", "tags": [ "third-party-advisory", "x_refsource_CERT" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-02" } ], "solutions": [ { "lang": "en", "value": "Upgrade to C-CURE 9000 version 2.80 or above. If this is not possible then follow published instructions for disabling the auto update feature located here https://support.swhouse.com/ and search for the document SWH-TAB-nID-000006545." } ], "source": { "discovery": "EXTERNAL" }, "title": "C-CURE 9000", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productsecurity@jci.com", "DATE_PUBLIC": "2021-07-01T06:01:00.000Z", "ID": "CVE-2021-27660", "STATE": "PUBLIC", "TITLE": "C-CURE 9000" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "C-CURE 9000", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "All versions of C-CURE 9000 prior to 2.80", "version_value": "2.80" } ] } } ] }, "vendor_name": "Johnson Controls" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An insecure client auto update feature in C-CURE 9000 can allow remote execution of lower privileged Windows programs." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories", "refsource": "CONFIRM", "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories" }, { "name": "ICS-CERT Advisory", "refsource": "CERT", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-02" } ] }, "solution": [ { "lang": "en", "value": "Upgrade to C-CURE 9000 version 2.80 or above. If this is not possible then follow published instructions for disabling the auto update feature located here https://support.swhouse.com/ and search for the document SWH-TAB-nID-000006545." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01", "assignerShortName": "jci", "cveId": "CVE-2021-27660", "datePublished": "2021-07-01T13:36:44.607216Z", "dateReserved": "2021-02-24T00:00:00", "dateUpdated": "2024-09-16T19:24:41.553Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-27660\",\"sourceIdentifier\":\"productsecurity@jci.com\",\"published\":\"2021-07-01T14:15:07.783\",\"lastModified\":\"2024-11-21T05:58:23.743\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An insecure client auto update feature in C-CURE 9000 can allow remote execution of lower privileged Windows programs.\"},{\"lang\":\"es\",\"value\":\"Una funcionalidad no segura de actualizaci\u00f3n autom\u00e1tica de clientes en C-CURE 9000, puede permitir una ejecuci\u00f3n remota de programas de Windows con menos privilegios\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productsecurity@jci.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productsecurity@jci.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:c-cure_9000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.80\",\"matchCriteriaId\":\"79BC2A60-BE5D-4308-B6A5-919DE1477CBD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:johnsoncontrols:c-cure_9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4291DD2F-EB08-4F19-98FB-C5CC8B4F3B7C\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-182-02\",\"source\":\"productsecurity@jci.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\",\"source\":\"productsecurity@jci.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-182-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…