CVE-2021-28213 (GCVE-0-2021-28213)
Vulnerability from cvelistv5
Published
2021-06-11 15:11
Modified
2024-08-03 21:40
Severity ?
CWE
  • Replacing example EDK II encrypted private key stored in PcdIpsecUefiCertificateKey presents potential security risks that will expose manufacturer key pair in EDK II.
Summary
Example EDK2 encrypted private key in the IpSecDxe.efi present potential security risks.
References
infosec@edk2.groups.io https://bugzilla.tianocore.org/show_bug.cgi?id=1866 Issue Tracking, Permissions Required, Vendor Advisory
af854a3a-2127-422b-91ae-364da2661108 https://bugzilla.tianocore.org/show_bug.cgi?id=1866 Issue Tracking, Permissions Required, Vendor Advisory
Impacted products
Vendor Product Version
TianoCore EDK II Version: edk2-stable201905
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T21:40:12.905Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1866"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EDK II",
          "vendor": "TianoCore",
          "versions": [
            {
              "status": "affected",
              "version": "edk2-stable201905"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Example EDK2 encrypted private key in the IpSecDxe.efi present potential security risks."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Replacing example EDK II encrypted private key stored in PcdIpsecUefiCertificateKey presents potential security risks that will expose manufacturer key pair in EDK II.",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-11T15:11:23",
        "orgId": "65518388-201a-4f93-8712-366d21fe8d2c",
        "shortName": "TianoCore"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1866"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "infosec@edk2.groups.io",
          "ID": "CVE-2021-28213",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EDK II",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "edk2-stable201905"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "TianoCore"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Example EDK2 encrypted private key in the IpSecDxe.efi present potential security risks."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Replacing example EDK II encrypted private key stored in PcdIpsecUefiCertificateKey presents potential security risks that will expose manufacturer key pair in EDK II."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.tianocore.org/show_bug.cgi?id=1866",
              "refsource": "MISC",
              "url": "https://bugzilla.tianocore.org/show_bug.cgi?id=1866"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "65518388-201a-4f93-8712-366d21fe8d2c",
    "assignerShortName": "TianoCore",
    "cveId": "CVE-2021-28213",
    "datePublished": "2021-06-11T15:11:23",
    "dateReserved": "2021-03-12T00:00:00",
    "dateUpdated": "2024-08-03T21:40:12.905Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-28213\",\"sourceIdentifier\":\"infosec@edk2.groups.io\",\"published\":\"2021-06-11T16:15:12.570\",\"lastModified\":\"2024-11-21T05:59:22.620\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Example EDK2 encrypted private key in the IpSecDxe.efi present potential security risks.\"},{\"lang\":\"es\",\"value\":\"La clave privada cifrada Example EDK2 en el archivo IpSecDxe.efi presenta riesgos potenciales de seguridad\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:tianocore:edk2:201905:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5A3F577A-A397-4185-B477-C31065B6F598\"}]}]}],\"references\":[{\"url\":\"https://bugzilla.tianocore.org/show_bug.cgi?id=1866\",\"source\":\"infosec@edk2.groups.io\",\"tags\":[\"Issue Tracking\",\"Permissions Required\",\"Vendor Advisory\"]},{\"url\":\"https://bugzilla.tianocore.org/show_bug.cgi?id=1866\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Issue Tracking\",\"Permissions Required\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…