CVE-2021-32006 (GCVE-0-2021-32006)
Vulnerability from cvelistv5
Published
2022-03-07 15:08
Modified
2024-08-03 23:17
CWE
  • CWE-275 - Permission Issues
  • CWE-274 - Improper Handling of Insufficient Privileges
Summary
This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files.
Impacted products
Vendor Product Version
Secomea GateManager Version: All   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:28.226Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GateManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThanOrEqual": "9.6.621421014",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Schlumberger"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-275",
              "description": "CWE-275 Permission Issues",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-274",
              "description": "CWE-274 Improper Handling of Insufficient Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-07T15:08:16",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-5018"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "GateManager information leak for LinkManager Users",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32006",
          "STATE": "PUBLIC",
          "TITLE": "GateManager information leak for LinkManager Users"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GateManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "9.6.621421014"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Schlumberger"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-275 Permission Issues"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-274 Improper Handling of Insufficient Privileges"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5018"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32006",
    "datePublished": "2022-03-07T15:08:16",
    "dateReserved": "2021-05-03T00:00:00",
    "dateUpdated": "2024-08-03T23:17:28.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-32006\",\"sourceIdentifier\":\"VulnerabilityReporting@secomea.com\",\"published\":\"2022-03-10T17:42:13.827\",\"lastModified\":\"2024-11-21T06:06:42.013\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files.\"},{\"lang\":\"es\",\"value\":\"Este problema afecta a: Secomea GateManager versi\u00f3n 9.6.621421014 y todas las versiones anteriores. Una vulnerabilidad de problemas de permisos en el portal web LinkManager de Secomea GateManager permite al usuario de LinkManager que ha iniciado sesi\u00f3n acceder a archivos de copia de seguridad de SiteManager almacenados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\",\"baseScore\":5.0,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.1,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-274\"},{\"lang\":\"en\",\"value\":\"CWE-275\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:secomea:gatemanager:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"9.6.621421014\",\"matchCriteriaId\":\"97FB8BBF-91E8-4C63-AD3C-0F04FA31690C\"}]}]}],\"references\":[{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Not Applicable\",\"Vendor Advisory\"]},{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…