CVE-2021-33841 (GCVE-0-2021-33841)
Vulnerability from cvelistv5
Published
2021-06-09 11:50
Modified
2024-09-16 17:59
Severity ?
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges.
Impacted products
Vendor Product Version
Circutor SGE-PLC1000 Version: 0.9.2b
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:58:23.191Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SGE-PLC1000",
          "vendor": "Circutor",
          "versions": [
            {
              "status": "affected",
              "version": "0.9.2b"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Industrial Cybersecurity team of S21sec, special mention to Aar\u00f3n Flecha Men\u00e9ndez."
        }
      ],
      "datePublic": "2021-06-07T22:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges."
            }
          ],
          "value": "SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-22T12:26:06.361Z",
        "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "shortName": "INCIBE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
            }
          ],
          "value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
        }
      ],
      "source": {
        "advisory": "INCIBE-2021-0227",
        "discovery": "EXTERNAL"
      },
      "title": "Circutor SGE-PLC1000 OS command Injection",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve-coordination@incibe.es",
          "DATE_PUBLIC": "2021-06-08T08:00:00.000Z",
          "ID": "CVE-2021-33841",
          "STATE": "PUBLIC",
          "TITLE": "Circutor SGE-PLC1000 OS command Injection"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SGE-PLC1000",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "0.9.2b",
                            "version_value": "0.9.2b"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Circutor"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Industrial Cybersecurity team of S21sec, special mention to Aar\u00f3n Flecha Men\u00e9ndez."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-os-command-injection",
              "refsource": "CONFIRM",
              "url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-os-command-injection"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
          }
        ],
        "source": {
          "advisory": "INCIBE-2021-0227",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
    "assignerShortName": "INCIBE",
    "cveId": "CVE-2021-33841",
    "datePublished": "2021-06-09T11:50:24.638155Z",
    "dateReserved": "2021-06-04T00:00:00",
    "dateUpdated": "2024-09-16T17:59:08.672Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-33841\",\"sourceIdentifier\":\"cve-coordination@incibe.es\",\"published\":\"2021-06-09T12:15:07.893\",\"lastModified\":\"2024-11-21T06:09:40.470\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges.\"},{\"lang\":\"es\",\"value\":\"Un dispositivo SGE-PLC1000, en su versi\u00f3n de firmware 0.9.2b, no maneja algunas petici\u00f3nes correctamente, permitiendo a un atacante remoto inyectar c\u00f3digo en el sistema operativo con m\u00e1ximos privilegios\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve-coordination@incibe.es\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cve-coordination@incibe.es\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5D6B02E0-DE36-45F5-AD3D-908E30548661\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFF41215-1018-42DD-9A7E-BBC2E5B4522D\"}]}]}],\"references\":[{\"url\":\"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection\",\"source\":\"cve-coordination@incibe.es\"},{\"url\":\"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…