CVE-2021-34602 (GCVE-0-2021-34602)
Vulnerability from cvelistv5
Published
2022-04-27 15:15
Modified
2024-09-17 01:46
CWE
  • CWE-78 - OS Command Injection
Summary
In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields that are executed with root privileges.
Impacted products
Vendor Product Version
Bender / ebee CC612 Version: 5.11.x   < 5.11.2
Version: 5.12.x   < 5.12.5
Version: 5.13.x   < 5.13.2
Version: 5.20.x   < 5.20.2
Create a notification for this product.
   Bender / ebee CC613 Version: 5.11.x   < 5.11.2
Version: 5.12.x   < 5.12.5
Version: 5.13.x   < 5.13.2
Version: 5.20.x   < 5.20.2
Create a notification for this product.
   Bender / ebee ICC15xx Version: 5.11.x   < 5.11.2
Version: 5.12.x   < 5.12.5
Version: 5.13.x   < 5.13.2
Version: 5.20.x   < 5.20.2
Create a notification for this product.
   Bender / ebee ICC16xx Version: 5.11.x   < 5.11.2
Version: 5.12.x   < 5.12.5
Version: 5.13.x   < 5.13.2
Version: 5.20.x   < 5.20.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:19:47.278Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-047"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CC612",
          "vendor": "Bender / ebee",
          "versions": [
            {
              "lessThan": "5.11.2",
              "status": "affected",
              "version": "5.11.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.12.5",
              "status": "affected",
              "version": "5.12.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.13.2",
              "status": "affected",
              "version": "5.13.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.20.2",
              "status": "affected",
              "version": "5.20.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CC613",
          "vendor": "Bender / ebee",
          "versions": [
            {
              "lessThan": "5.11.2",
              "status": "affected",
              "version": "5.11.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.12.5",
              "status": "affected",
              "version": "5.12.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.13.2",
              "status": "affected",
              "version": "5.13.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.20.2",
              "status": "affected",
              "version": "5.20.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ICC15xx",
          "vendor": "Bender / ebee",
          "versions": [
            {
              "lessThan": "5.11.2",
              "status": "affected",
              "version": "5.11.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.12.5",
              "status": "affected",
              "version": "5.12.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.13.2",
              "status": "affected",
              "version": "5.13.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.20.2",
              "status": "affected",
              "version": "5.20.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "ICC16xx",
          "vendor": "Bender / ebee",
          "versions": [
            {
              "lessThan": "5.11.2",
              "status": "affected",
              "version": "5.11.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.12.5",
              "status": "affected",
              "version": "5.12.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.13.2",
              "status": "affected",
              "version": "5.13.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.20.2",
              "status": "affected",
              "version": "5.20.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Bender thanks Qianxin StarV Security Lab, China. The issue was coordinated by CERT@VDE."
        }
      ],
      "datePublic": "2022-04-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields that are executed with root privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-27T15:15:34",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-047"
        }
      ],
      "source": {
        "advisory": "VDE-2021-047",
        "defect": [
          "CERT@VDE#64027"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Bender Charge Controller: Long URL could lead to webserver crash",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-27T10:00:00.000Z",
          "ID": "CVE-2021-34602",
          "STATE": "PUBLIC",
          "TITLE": "Bender Charge Controller: Long URL could lead to webserver crash"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CC612",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.11.x",
                            "version_value": "5.11.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.12.x",
                            "version_value": "5.12.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.13.x",
                            "version_value": "5.13.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.20.x",
                            "version_value": "5.20.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CC613",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.11.x",
                            "version_value": "5.11.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.12.x",
                            "version_value": "5.12.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.13.x",
                            "version_value": "5.13.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.20.x",
                            "version_value": "5.20.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ICC15xx",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.11.x",
                            "version_value": "5.11.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.12.x",
                            "version_value": "5.12.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.13.x",
                            "version_value": "5.13.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.20.x",
                            "version_value": "5.20.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "ICC16xx",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.11.x",
                            "version_value": "5.11.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.12.x",
                            "version_value": "5.12.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.13.x",
                            "version_value": "5.13.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.20.x",
                            "version_value": "5.20.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bender / ebee"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Bender thanks Qianxin StarV Security Lab, China. The issue was coordinated by CERT@VDE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields that are executed with root privileges."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78 OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-047",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-047"
            }
          ]
        },
        "source": {
          "advisory": "VDE-2021-047",
          "defect": [
            "CERT@VDE#64027"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2021-34602",
    "datePublished": "2022-04-27T15:15:34.774811Z",
    "dateReserved": "2021-06-10T00:00:00",
    "dateUpdated": "2024-09-17T01:46:57.289Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-34602\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2022-04-27T16:15:11.267\",\"lastModified\":\"2024-11-21T06:10:47.783\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields that are executed with root privileges.\"},{\"lang\":\"es\",\"value\":\"En los controladores de carga Bender/ebee en m\u00faltiples versiones son propensos a la inyecci\u00f3n de comandos por medio de la interfaz web. Un atacante autenticado podr\u00eda introducir comandos de shell en algunos campos de entrada que son ejecutados con privilegios root\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:cc612_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.11.0\",\"versionEndExcluding\":\"5.11.2\",\"matchCriteriaId\":\"81AED2C8-71EE-4BFC-949C-D63F998CD1ED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:cc612_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.12.0\",\"versionEndExcluding\":\"5.12.5\",\"matchCriteriaId\":\"609125CC-4748-4507-8CF2-1752FF89B203\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:cc612_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.13.0\",\"versionEndExcluding\":\"5.13.2\",\"matchCriteriaId\":\"C6FEC2C0-7F12-434A-9070-9A0F19379D25\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:cc612_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.20.0\",\"versionEndExcluding\":\"5.20.2\",\"matchCriteriaId\":\"E80EBD0C-D852-4EF7-B0EA-89124683939C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bender:cc612:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9B48F3A5-C59D-40B6-ADBB-76FA536C78FE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.11.0\",\"versionEndExcluding\":\"5.11.2\",\"matchCriteriaId\":\"4B078039-C644-42DE-8122-300415D69854\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.12.0\",\"versionEndExcluding\":\"5.12.5\",\"matchCriteriaId\":\"D687057F-58C9-4463-BEF2-BE4CA428F9AD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.13.0\",\"versionEndExcluding\":\"5.13.2\",\"matchCriteriaId\":\"88D208BE-6401-489E-BBE7-1ABBEB14CF52\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.20.0\",\"versionEndExcluding\":\"5.20.2\",\"matchCriteriaId\":\"0B36AF92-1F52-45AA-BAAF-0D94EB0B2FF2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bender:cc613:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2FEFDDEB-23FB-474C-9A91-EDA35837D34B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.11.0\",\"versionEndExcluding\":\"5.11.2\",\"matchCriteriaId\":\"4B078039-C644-42DE-8122-300415D69854\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.12.0\",\"versionEndExcluding\":\"5.12.5\",\"matchCriteriaId\":\"D687057F-58C9-4463-BEF2-BE4CA428F9AD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.13.0\",\"versionEndExcluding\":\"5.13.2\",\"matchCriteriaId\":\"88D208BE-6401-489E-BBE7-1ABBEB14CF52\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.20.0\",\"versionEndExcluding\":\"5.20.2\",\"matchCriteriaId\":\"0B36AF92-1F52-45AA-BAAF-0D94EB0B2FF2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bender:cc613:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2FEFDDEB-23FB-474C-9A91-EDA35837D34B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.11.0\",\"versionEndExcluding\":\"5.11.2\",\"matchCriteriaId\":\"4B078039-C644-42DE-8122-300415D69854\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.12.0\",\"versionEndExcluding\":\"5.12.5\",\"matchCriteriaId\":\"D687057F-58C9-4463-BEF2-BE4CA428F9AD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.13.0\",\"versionEndExcluding\":\"5.13.2\",\"matchCriteriaId\":\"88D208BE-6401-489E-BBE7-1ABBEB14CF52\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.20.0\",\"versionEndExcluding\":\"5.20.2\",\"matchCriteriaId\":\"0B36AF92-1F52-45AA-BAAF-0D94EB0B2FF2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bender:cc613:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2FEFDDEB-23FB-474C-9A91-EDA35837D34B\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2021-047\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2021-047\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…