CVE-2022-0835 (GCVE-0-2022-0835)
Vulnerability from cvelistv5
Published
2022-04-11 19:38
Modified
2025-04-16 17:56
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-316 - Cleartext Storage of Sensitive Information in Memory
Summary
AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user.
References
► | URL | Tags | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
AVEVA | AVEVA System Platform |
Version: 5.59 2020 R2 P01 Version: 2020 R2S Version: 2020 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T23:40:04.450Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-0835", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-04-16T17:29:59.891448Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-16T17:56:24.023Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AVEVA System Platform", "vendor": "AVEVA", "versions": [ { "status": "affected", "version": "5.59 2020 R2 P01" }, { "status": "affected", "version": "2020 R2S" }, { "status": "affected", "version": "2020" } ] } ], "credits": [ { "lang": "en", "value": "Noam Moshe of Claroty and Ilya Karpov, Evgeniy Druzhinin, and Konstantin Kondratev of Rostelecom-Solar reported this vulnerability to AVEVA." } ], "descriptions": [ { "lang": "en", "value": "AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-316", "description": "CWE-316: Cleartext Storage of Sensitive Information in Memory", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-11T19:38:30.000Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf" } ], "solutions": [ { "lang": "en", "value": "AVEVA recommends users of affected versions upgrade to one of the versions listed below and apply the corresponding security update:\n\u2022\tAVEVA System Platform 2020 R2 P01 and AVEVA System Platform 2020 R2: update to AVEVA System Platform 2020 R2 SP1\n\u2022\tAVEVA System Platform 2020: update to AVEVA System Platform 2020 P01\n\nFor more information on this issue, including security updates, please see Security Bulletin AVEVA-2021-007\n" } ], "source": { "advisory": "ICSA-22-067-02", "discovery": "EXTERNAL" }, "title": "AVEVA System Platform Cleartext Storage of Sensitive Information in Memory", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-0835", "STATE": "PUBLIC", "TITLE": "AVEVA System Platform Cleartext Storage of Sensitive Information in Memory" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "AVEVA System Platform", "version": { "version_data": [ { "version_affected": "=", "version_name": "5.59", "version_value": "2020 R2 P01" }, { "version_value": "2020 R2S" }, { "version_value": "2020" } ] } } ] }, "vendor_name": "AVEVA" } ] } }, "credit": [ { "lang": "eng", "value": "Noam Moshe of Claroty and Ilya Karpov, Evgeniy Druzhinin, and Konstantin Kondratev of Rostelecom-Solar reported this vulnerability to AVEVA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-316: Cleartext Storage of Sensitive Information in Memory" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02" }, { "name": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf", "refsource": "CONFIRM", "url": "https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf" } ] }, "solution": [ { "lang": "en", "value": "AVEVA recommends users of affected versions upgrade to one of the versions listed below and apply the corresponding security update:\n\u2022\tAVEVA System Platform 2020 R2 P01 and AVEVA System Platform 2020 R2: update to AVEVA System Platform 2020 R2 SP1\n\u2022\tAVEVA System Platform 2020: update to AVEVA System Platform 2020 P01\n\nFor more information on this issue, including security updates, please see Security Bulletin AVEVA-2021-007\n" } ], "source": { "advisory": "ICSA-22-067-02", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-0835", "datePublished": "2022-04-11T19:38:30.000Z", "dateReserved": "2022-03-02T00:00:00.000Z", "dateUpdated": "2025-04-16T17:56:24.023Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-0835\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-04-11T20:15:16.540\",\"lastModified\":\"2024-11-21T06:39:29.600\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user.\"},{\"lang\":\"es\",\"value\":\"AVEVA System Platform versi\u00f3n 2020, almacena informaci\u00f3n confidencial en texto sin cifrar, lo que puede permitir el acceso a un atacante o a un usuario con pocos privilegios\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.5,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":1.9,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.4,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-316\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:aveva:system_platform:2020:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"D47F4B07-B67F-4855-AED2-D17B0E76FA8A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:aveva:system_platform:2020:r2_patch01:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F27FDBD-1469-4E27-BB80-81D6C80CECF5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:aveva:system_platform:2020:r2s:*:*:*:*:*:*\",\"matchCriteriaId\":\"5153D135-6C47-4980-BEB2-A14531F9476B\"}]}]}],\"references\":[{\"url\":\"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}, {\"url\": \"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T23:40:04.450Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-0835\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T17:29:59.891448Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T17:30:01.856Z\"}}], \"cna\": {\"title\": \"AVEVA System Platform Cleartext Storage of Sensitive Information in Memory\", \"source\": {\"advisory\": \"ICSA-22-067-02\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"Noam Moshe of Claroty and Ilya Karpov, Evgeniy Druzhinin, and Konstantin Kondratev of Rostelecom-Solar reported this vulnerability to AVEVA.\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.1, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"AVEVA\", \"product\": \"AVEVA System Platform\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.59 2020 R2 P01\"}, {\"status\": \"affected\", \"version\": \"2020 R2S\"}, {\"status\": \"affected\", \"version\": \"2020\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"AVEVA recommends users of affected versions upgrade to one of the versions listed below and apply the corresponding security update:\\n\\u2022\\tAVEVA System Platform 2020 R2 P01 and AVEVA System Platform 2020 R2: update to AVEVA System Platform 2020 R2 SP1\\n\\u2022\\tAVEVA System Platform 2020: update to AVEVA System Platform 2020 P01\\n\\nFor more information on this issue, including security updates, please see Security Bulletin AVEVA-2021-007\\n\"}], \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02\", \"tags\": [\"x_refsource_CONFIRM\"]}, {\"url\": \"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf\", \"tags\": [\"x_refsource_CONFIRM\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-316\", \"description\": \"CWE-316: Cleartext Storage of Sensitive Information in Memory\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-04-11T19:38:30.000Z\"}, \"x_legacyV4Record\": {\"credit\": [{\"lang\": \"eng\", \"value\": \"Noam Moshe of Claroty and Ilya Karpov, Evgeniy Druzhinin, and Konstantin Kondratev of Rostelecom-Solar reported this vulnerability to AVEVA.\"}], \"impact\": {\"cvss\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.1, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}, \"source\": {\"advisory\": \"ICSA-22-067-02\", \"discovery\": \"EXTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_name\": \"5.59\", \"version_value\": \"2020 R2 P01\", \"version_affected\": \"=\"}, {\"version_value\": \"2020 R2S\"}, {\"version_value\": \"2020\"}]}, \"product_name\": \"AVEVA System Platform\"}]}, \"vendor_name\": \"AVEVA\"}]}}, \"solution\": [{\"lang\": \"en\", \"value\": \"AVEVA recommends users of affected versions upgrade to one of the versions listed below and apply the corresponding security update:\\n\\u2022\\tAVEVA System Platform 2020 R2 P01 and AVEVA System Platform 2020 R2: update to AVEVA System Platform 2020 R2 SP1\\n\\u2022\\tAVEVA System Platform 2020: update to AVEVA System Platform 2020 P01\\n\\nFor more information on this issue, including security updates, please see Security Bulletin AVEVA-2021-007\\n\"}], \"data_type\": \"CVE\", \"generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"references\": {\"reference_data\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02\", \"name\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-02\", \"refsource\": \"CONFIRM\"}, {\"url\": \"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf\", \"name\": \"https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2021-007.pdf\", \"refsource\": \"CONFIRM\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"AVEVA System Platform 2020 stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-316: Cleartext Storage of Sensitive Information in Memory\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-0835\", \"STATE\": \"PUBLIC\", \"TITLE\": \"AVEVA System Platform Cleartext Storage of Sensitive Information in Memory\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\"}}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-0835\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-16T17:56:24.023Z\", \"dateReserved\": \"2022-03-02T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2022-04-11T19:38:30.000Z\", \"assignerShortName\": \"icscert\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…