CVE-2022-29830 (GCVE-0-2022-29830)
Vulnerability from cvelistv5
Published
2022-11-24 23:23
Modified
2025-04-25 17:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-321 - Use of Hard-coded Cryptographic Key
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Mitsubishi Electric Corporation | GX Works3 |
Version: from 1.000A to 1.095Z |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:33:43.144Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU97244961/index.html" }, { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-29830", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-04-25T17:50:31.923830Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-25T17:50:37.066Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "GX Works3", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "from 1.000A to 1.095Z" } ] }, { "defaultStatus": "unaffected", "product": "Motion Control Setting(GX Works3 related software)", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "from 1.000A and later" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally." } ], "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-321", "description": "CWE-321 Use of Hard-coded Cryptographic Key", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-29T07:42:35.363Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU97244961/index.html" }, { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2022-29830", "datePublished": "2022-11-24T23:23:51.967Z", "dateReserved": "2022-04-27T20:47:43.443Z", "dateUpdated": "2025-04-25T17:50:37.066Z", "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-29830\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2022-11-25T00:15:10.367\",\"lastModified\":\"2024-11-21T06:59:46.313\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.\"},{\"lang\":\"es\",\"value\":\"El uso de una vulnerabilidad de clave criptogr\u00e1fica codificada en Mitsubishi Electric GX Works3 en las versiones 1.000A hasta 1.095Z y la configuraci\u00f3n de control de movimiento (software relacionado con GX Works3) de 1.000A y posteriores permite a un atacante remoto no autenticado revelar o alterar informaci\u00f3n sensible. Como resultado, los atacantes no autenticados pueden obtener informaci\u00f3n sobre archivos de proyecto de forma ilegal.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-321\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.000a\",\"versionEndIncluding\":\"1.011m\",\"matchCriteriaId\":\"A868567B-2BAA-45AE-AEC9-3AFEF2361297\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.015r\",\"versionEndIncluding\":\"1.086q\",\"matchCriteriaId\":\"56BD062B-0D41-42E2-B9EF-B7FBB514CFF9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.087r\",\"matchCriteriaId\":\"C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU97244961/index.html\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\"},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/vu/JVNVU97244961/index.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU97244961/index.html\", \"tags\": [\"government-resource\", \"x_transferred\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\", \"tags\": [\"government-resource\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T06:33:43.144Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-29830\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-25T17:50:31.923830Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-25T17:50:27.373Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GX Works3\", \"versions\": [{\"status\": \"affected\", \"version\": \"from 1.000A to 1.095Z\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Motion Control Setting(GX Works3 related software)\", \"versions\": [{\"status\": \"affected\", \"version\": \"from 1.000A and later\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU97244961/index.html\", \"tags\": [\"government-resource\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05\", \"tags\": [\"government-resource\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-321\", \"description\": \"CWE-321 Use of Hard-coded Cryptographic Key\"}]}], \"providerMetadata\": {\"orgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"shortName\": \"Mitsubishi\", \"dateUpdated\": \"2023-06-29T07:42:35.363Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-29830\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-25T17:50:37.066Z\", \"dateReserved\": \"2022-04-27T20:47:43.443Z\", \"assignerOrgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"datePublished\": \"2022-11-24T23:23:51.967Z\", \"requesterUserId\": \"520cc88b-a1c8-44f6-9154-21a4d74c769f\", \"assignerShortName\": \"Mitsubishi\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…