Summary
A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of an user, such as credentials, in case that user's id is known.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | SICAM GridEdge Essential ARM |
Version: All versions < V2.6.6 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:40:47.813Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-631336.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM GridEdge Essential ARM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6.6" } ] }, { "product": "SICAM GridEdge Essential Intel", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6.6" } ] }, { "product": "SICAM GridEdge Essential with GDS ARM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6.6" } ] }, { "product": "SICAM GridEdge Essential with GDS Intel", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6.6" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions \u003c V2.6.6), SICAM GridEdge Essential Intel (All versions \u003c V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions \u003c V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions \u003c V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of an user, such as credentials, in case that user\u0027s id is known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-06-14T09:21:50", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-631336.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-30229", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM GridEdge Essential ARM", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6.6" } ] } }, { "product_name": "SICAM GridEdge Essential Intel", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6.6" } ] } }, { "product_name": "SICAM GridEdge Essential with GDS ARM", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6.6" } ] } }, { "product_name": "SICAM GridEdge Essential with GDS Intel", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6.6" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions \u003c V2.6.6), SICAM GridEdge Essential Intel (All versions \u003c V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions \u003c V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions \u003c V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of an user, such as credentials, in case that user\u0027s id is known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-631336.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-631336.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-30229", "datePublished": "2022-06-14T09:21:50", "dateReserved": "2022-05-04T00:00:00", "dateUpdated": "2024-08-03T06:40:47.813Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-30229\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-06-14T10:15:20.320\",\"lastModified\":\"2024-11-21T07:02:24.027\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions \u003c V2.6.6), SICAM GridEdge Essential Intel (All versions \u003c V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions \u003c V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions \u003c V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of an user, such as credentials, in case that user\u0027s id is known.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SICAM GridEdge Essential ARM (Todas las versiones anteriores a V2.6.6), SICAM GridEdge Essential Intel (Todas las versiones anteriores a V2.6.6), SICAM GridEdge Essential con GDS ARM (Todas las versiones anteriores a V2.6.6), SICAM GridEdge Essential con GDS Intel (Todas las versiones anteriores a V2.6.6). El software afectado no requiere acceso autenticado para las funciones privilegiadas. Esto podr\u00eda permitir a un atacante no autenticado cambiar los datos de un usuario, como las credenciales, en caso de que sea conocida la identidad de ese usuario\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sicam_gridedge_essential:*:*:*:*:arm:*:*:*\",\"versionEndExcluding\":\"2.6.6\",\"matchCriteriaId\":\"0A9DFD18-74F8-4937-8BA1-D4E32F39C96D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sicam_gridedge_essential:*:*:*:*:gds_arm:*:*:*\",\"versionEndExcluding\":\"2.6.6\",\"matchCriteriaId\":\"F0EBFD11-7825-492D-8322-03B53DE9F727\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sicam_gridedge_essential:*:*:*:*:gds_intel:*:*:*\",\"versionEndExcluding\":\"2.6.6\",\"matchCriteriaId\":\"11979179-F642-4FA3-9E6F-06D6336510D4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sicam_gridedge_essential:*:*:*:*:intel:*:*:*\",\"versionEndExcluding\":\"2.6.6\",\"matchCriteriaId\":\"C882E87E-3550-4E2D-999B-BF09663DDEAA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-631336.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-631336.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…