CVE-2022-3369 (GCVE-0-2022-3369)
Vulnerability from cvelistv5
Published
2022-11-01 07:45
Modified
2025-05-02 16:06
CWE
  • CWE-269 - Improper Privilege Management
Summary
An Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659.
Impacted products
Vendor Product Version
Bitdefender Engines Version: unspecified   < 7.92659
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:07:06.576Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3369",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-02T16:05:49.235759Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-02T16:06:44.011Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Engines",
          "vendor": "Bitdefender",
          "versions": [
            {
              "lessThan": "7.92659",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-10-31T22:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659.\u003c/p\u003e"
            }
          ],
          "value": "An Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-20T09:18:28.055Z",
        "orgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
        "shortName": "Bitdefender"
      },
      "references": [
        {
          "url": "https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn automatic update to Engines version 7.92659 fixes the issue.\u003c/p\u003e"
            }
          ],
          "value": "An automatic update to Engines version 7.92659 fixes the issue."
        }
      ],
      "source": {
        "defect": [
          "VA-10562"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Improper handling of registry symbolic links in Bitdefender Engines",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
    "assignerShortName": "Bitdefender",
    "cveId": "CVE-2022-3369",
    "datePublished": "2022-11-01T07:45:19.436Z",
    "dateReserved": "2022-09-30T00:00:00.000Z",
    "dateUpdated": "2025-05-02T16:06:44.011Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-3369\",\"sourceIdentifier\":\"cve-requests@bitdefender.com\",\"published\":\"2022-11-01T08:15:10.097\",\"lastModified\":\"2024-11-21T07:19:23.107\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de control de acceso inadecuado en el componente bdservicehost.exe, tal como se utiliza en Bitdefender Engines para Windows, permite a un atacante eliminar claves de registro privilegiadas apuntando un enlace simb\u00f3lico del Registro a una clave privilegiada. Este problema afecta a: Versiones de Bitdefender Engines anteriores a la 7.92659. Tambi\u00e9n afecta a Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as\u00ed como a Bitdefender Endpoint Security Tools para Windows con versiones de motor anteriores a la 7.92659.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve-requests@bitdefender.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cve-requests@bitdefender.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bitdefender:engines:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.92659\",\"matchCriteriaId\":\"DF34CDC6-E05A-4B00-AAF6-28FF0E9479D8\"}]}]}],\"references\":[{\"url\":\"https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562\",\"source\":\"cve-requests@bitdefender.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T01:07:06.576Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-3369\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-02T16:05:49.235759Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-02T16:05:56.793Z\"}}], \"cna\": {\"title\": \"Improper handling of registry symbolic links in Bitdefender Engines\", \"source\": {\"defect\": [\"VA-10562\"], \"discovery\": \"EXTERNAL\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.6, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Bitdefender\", \"product\": \"Engines\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"lessThan\": \"7.92659\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"An automatic update to Engines version 7.92659 fixes the issue.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eAn automatic update to Engines version 7.92659 fixes the issue.\u003c/p\u003e\", \"base64\": false}]}], \"datePublic\": \"2022-10-31T22:00:00.000Z\", \"references\": [{\"url\": \"https://www.bitdefender.com/support/security-advisories/improper-handling-of-registry-symbolic-links-in-bitdefender-engines-va-10562\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eAn Improper Access Control vulnerability in the bdservicehost.exe component, as used in Bitdefender Engines for Windows, allows an attacker to delete privileged registry keys by pointing a Registry symlink to a privileged key. This issue affects: Bitdefender Engines versions prior to 7.92659. It also affects Bitdefender Antivirus Free, Bitdefender Antivirus Plus, Bitdefender Internet Security, Bitdefender Total Security, as well as Bitdefender Endpoint Security Tools for Windows with engine versions prior to 7.92659.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-269\", \"description\": \"CWE-269 Improper Privilege Management\"}]}], \"providerMetadata\": {\"orgId\": \"b3d5ebe7-963e-41fb-98e1-2edaeabb8f82\", \"shortName\": \"Bitdefender\", \"dateUpdated\": \"2022-12-20T09:18:28.055Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-3369\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-02T16:06:44.011Z\", \"dateReserved\": \"2022-09-30T00:00:00.000Z\", \"assignerOrgId\": \"b3d5ebe7-963e-41fb-98e1-2edaeabb8f82\", \"datePublished\": \"2022-11-01T07:45:19.436Z\", \"assignerShortName\": \"Bitdefender\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…