CVE-2022-45140 (GCVE-0-2022-45140)
Vulnerability from cvelistv5
Published
2023-02-27 14:36
Modified
2025-03-10 17:46
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | WAGO | Compact Controller CC100 (751-9301) |
Version: FW16 < FW22 Version: FW23 |
|||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:09:55.436Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2022-060/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-45140", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-10T17:46:43.476712Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-10T17:46:52.078Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Compact Controller CC100 (751-9301)", "vendor": "WAGO", "versions": [ { "lessThan": "FW22", "status": "affected", "version": "FW16", "versionType": "custom" }, { "status": "unaffected", "version": "FW22 Patch 1" }, { "status": "affected", "version": "FW23" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller (752-8303/8000-002)", "vendor": "WAGO", "versions": [ { "lessThan": "FW22", "status": "affected", "version": "FW16", "versionType": "custom" }, { "status": "unaffected", "version": "FW22 Patch 1" }, { "status": "affected", "version": "FW23" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 (750-81xx/xxx-xxx)", "vendor": "WAGO", "versions": [ { "lessThan": "FW22", "status": "affected", "version": "FW16", "versionType": "custom" }, { "status": "unaffected", "version": "FW22 Patch 1" }, { "status": "affected", "version": "FW23" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 (750-82xx/xxx-xxx)", "vendor": "WAGO", "versions": [ { "lessThan": "FW22", "status": "affected", "version": "FW16", "versionType": "custom" }, { "status": "unaffected", "version": "FW22 Patch 1" }, { "status": "affected", "version": "FW23" } ] }, { "defaultStatus": "unaffected", "product": "Touch Panel 600 Advanced Line (762-5xxx)", "vendor": "WAGO", "versions": [ { "lessThan": "FW22", "status": "affected", "version": "FW16", "versionType": "custom" }, { "status": "unaffected", "version": "FW22 Patch 1" }, { "status": "affected", "version": "FW23" } ] }, { "defaultStatus": "unaffected", "product": "Touch Panel 600 Marine Line (762-6xxx)", "vendor": "WAGO", "versions": [ { "lessThan": "FW22", "status": "affected", "version": "FW16", "versionType": "custom" }, { "status": "unaffected", "version": "FW22 Patch 1" }, { "status": "affected", "version": "FW23" } ] }, { "defaultStatus": "unaffected", "product": "Touch Panel 600 Standard Line (762-4xxx)", "vendor": "WAGO", "versions": [ { "lessThan": "FW22", "status": "affected", "version": "FW16", "versionType": "custom" }, { "status": "unaffected", "version": "FW22 Patch 1" }, { "status": "affected", "version": "FW23" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise." } ], "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise." } ], "impacts": [ { "capecId": "CAPEC-115", "descriptions": [ { "lang": "en", "value": "CAPEC-115 Authentication Bypass" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-27T14:36:39.448Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2022-060/" } ], "source": { "defect": [ "CERT@VDE#64160" ], "discovery": "UNKNOWN" }, "title": "WAGO: Missing Authentication for Critical Function ", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-45140", "datePublished": "2023-02-27T14:36:39.448Z", "dateReserved": "2022-11-10T09:46:59.080Z", "dateUpdated": "2025-03-10T17:46:52.078Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-45140\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2023-02-27T15:15:11.503\",\"lastModified\":\"2024-11-21T07:28:50.143\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:751-9301_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndExcluding\":\"22\",\"matchCriteriaId\":\"D694685C-2D87-4C94-9957-6B921E8836CF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:751-9301_firmware:22:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E42B14D3-F36A-4213-8447-870E9FC60F48\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:751-9301_firmware:23:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"84839593-47AD-47C1-8762-FAF10070BCAD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:751-9301:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"385FE0DA-6383-4EF7-835A-055EB0D22EB8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:752-8303\\\\/8000-002_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"18\",\"versionEndExcluding\":\"22\",\"matchCriteriaId\":\"4958E9ED-6410-4F34-B582-7532A7F3101C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:752-8303\\\\/8000-002_firmware:22:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4761AA7-B270-485C-B929-34384145DCBB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:752-8303\\\\/8000-002_firmware:23:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B514966-03EE-4710-89C0-E8FE771E79CD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:752-8303\\\\/8000-002:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"915B0745-EB00-40AD-80BA-887EFB435901\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc100_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndExcluding\":\"22\",\"matchCriteriaId\":\"D0044A0A-90FD-4C5E-B1F9-A7A0B9EF0BE8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc100_firmware:22:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4815DFF8-0CAE-4C85-9F5B-F64C12F43AB0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc100_firmware:23:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2C84D09E-A681-47F1-AC37-850BF6E47D01\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F636354-95A2-4B36-9666-1FA57F185432\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndExcluding\":\"22\",\"matchCriteriaId\":\"EEF2D886-205E-46D2-80DA-2E594F867EE5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc200_firmware:22:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"B876DC19-0523-41DB-8BD7-1ECC09FCFA01\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc200_firmware:23:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BE108CD0-B451-4ED5-83A1-CCEAACC1B40C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"688A3248-7EAA-499D-A47C-A4D4900CDBD1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_advanced_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndExcluding\":\"22\",\"matchCriteriaId\":\"FE5248EE-90DF-446C-BC44-D5AF5EDB45A1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_advanced_firmware:22:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"9A613D7C-29C0-4D4E-ACDA-15BBC6FF0104\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_advanced_firmware:23:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D06AC6E-2EB2-4ACB-A6CA-E7AB88540713\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_advanced:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8221861-7455-41D5-B310-6AEA822B46CF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_marine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndExcluding\":\"22\",\"matchCriteriaId\":\"0FF35303-B999-40FE-8DC1-C18243F13FE7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_marine_firmware:22:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"774CFF47-61B6-48F8-8E1F-E3DC215066AF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_marine_firmware:23:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CD092B48-C42A-409E-AC9C-F523AD654C1B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_marine:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83DEFFBC-934D-43BE-92AE-25F8EE8C1E0A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_standard_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndExcluding\":\"22\",\"matchCriteriaId\":\"9B8C054D-F02F-48A0-85D0-DFF90E9C31BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_standard_firmware:22:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA7A911A-395A-4536-8756-83DB2F62899D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_standard_firmware:23:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"263C0C64-F5B4-43C3-BF26-AF24DFA74699\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_standard:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6D7A44C-2D95-4F69-A7DB-435B0A6F9F03\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-060/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-060/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-060/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T14:09:55.436Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-45140\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-03-10T17:46:43.476712Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-03-10T17:46:48.522Z\"}}], \"cna\": {\"title\": \"WAGO: Missing Authentication for Critical Function \", \"source\": {\"defect\": [\"CERT@VDE#64160\"], \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab\"}], \"impacts\": [{\"capecId\": \"CAPEC-115\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-115 Authentication Bypass\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"WAGO\", \"product\": \"Compact Controller CC100 (751-9301)\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW16\", \"lessThan\": \"FW22\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"FW22 Patch 1\"}, {\"status\": \"affected\", \"version\": \"FW23\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"WAGO\", \"product\": \"Edge Controller (752-8303/8000-002)\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW16\", \"lessThan\": \"FW22\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"FW22 Patch 1\"}, {\"status\": \"affected\", \"version\": \"FW23\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"WAGO\", \"product\": \"PFC100 (750-81xx/xxx-xxx)\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW16\", \"lessThan\": \"FW22\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"FW22 Patch 1\"}, {\"status\": \"affected\", \"version\": \"FW23\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"WAGO\", \"product\": \"PFC200 (750-82xx/xxx-xxx)\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW16\", \"lessThan\": \"FW22\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"FW22 Patch 1\"}, {\"status\": \"affected\", \"version\": \"FW23\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"WAGO\", \"product\": \"Touch Panel 600 Advanced Line (762-5xxx)\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW16\", \"lessThan\": \"FW22\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"FW22 Patch 1\"}, {\"status\": \"affected\", \"version\": \"FW23\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"WAGO\", \"product\": \"Touch Panel 600 Marine Line (762-6xxx)\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW16\", \"lessThan\": \"FW22\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"FW22 Patch 1\"}, {\"status\": \"affected\", \"version\": \"FW23\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"WAGO\", \"product\": \"Touch Panel 600 Standard Line (762-4xxx)\", \"versions\": [{\"status\": \"affected\", \"version\": \"FW16\", \"lessThan\": \"FW22\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"FW22 Patch 1\"}, {\"status\": \"affected\", \"version\": \"FW23\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-060/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306 Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2023-02-27T14:36:39.448Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-45140\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-10T17:46:52.078Z\", \"dateReserved\": \"2022-11-10T09:46:59.080Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2023-02-27T14:36:39.448Z\", \"assignerShortName\": \"CERTVDE\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…