Summary
The bluetooth HCI host layer logic not clearing a global reference to a semaphore after synchronously sending HCI commands may allow a malicious HCI Controller to cause the use of a dangling reference in the host layer, leading to a crash (DoS) or potential RCE on the Host layer.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:05:26.711Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-xvvm-8mcm-9cq3"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:zephyrproject:zephyr:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "zephyr",
            "vendor": "zephyrproject",
            "versions": [
              {
                "lessThanOrEqual": "3.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-1901",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-07T15:11:58.244687Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-672",
                "description": "CWE-672 Operation on a Resource after Expiration or Release",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-07T15:19:24.502Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "packageName": "Zephyr",
          "product": "Zephyr",
          "repo": "https://github.com/zephyrproject-rtos/zephyr",
          "vendor": "zephyrproject-rtos",
          "versions": [
            {
              "lessThanOrEqual": "3.3",
              "status": "affected",
              "version": "*",
              "versionType": "git"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The bluetooth HCI host layer logic not clearing a global reference to a semaphore after synchronously sending HCI commands may allow a malicious HCI Controller to cause the use of a dangling reference in the host layer, leading to a crash (DoS) or potential RCE on the Host layer.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "The bluetooth HCI host layer logic not clearing a global reference to a semaphore after synchronously sending HCI commands may allow a malicious HCI Controller to cause the use of a dangling reference in the host layer, leading to a crash (DoS) or potential RCE on the Host layer.\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-10T04:37:33.126Z",
        "orgId": "e2e69745-5e70-4e92-8431-deb5529a81ad",
        "shortName": "zephyr"
      },
      "references": [
        {
          "url": "https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-xvvm-8mcm-9cq3"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "HCI send_sync Dangling Semaphore Reference Re-use",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e2e69745-5e70-4e92-8431-deb5529a81ad",
    "assignerShortName": "zephyr",
    "cveId": "CVE-2023-1901",
    "datePublished": "2023-07-10T04:37:33.126Z",
    "dateReserved": "2023-04-05T22:11:42.140Z",
    "dateUpdated": "2024-11-07T15:19:24.502Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-1901\",\"sourceIdentifier\":\"vulnerabilities@zephyrproject.org\",\"published\":\"2023-07-10T16:15:49.003\",\"lastModified\":\"2024-11-21T07:40:06.653\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The bluetooth HCI host layer logic not clearing a global reference to a semaphore after synchronously sending HCI commands may allow a malicious HCI Controller to cause the use of a dangling reference in the host layer, leading to a crash (DoS) or potential RCE on the Host layer.\\n\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"vulnerabilities@zephyrproject.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:H\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":4.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.0,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.1,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-672\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zephyrproject:zephyr:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.3.0\",\"matchCriteriaId\":\"E2D56E6F-F247-436A-B6F4-FA7263D4C5E2\"}]}]}],\"references\":[{\"url\":\"https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-xvvm-8mcm-9cq3\",\"source\":\"vulnerabilities@zephyrproject.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-xvvm-8mcm-9cq3\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-xvvm-8mcm-9cq3\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T06:05:26.711Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-1901\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-07T15:11:58.244687Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:zephyrproject:zephyr:*:*:*:*:*:*:*:*\"], \"vendor\": \"zephyrproject\", \"product\": \"zephyr\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"3.3\"}], \"defaultStatus\": \"unknown\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-672\", \"description\": \"CWE-672 Operation on a Resource after Expiration or Release\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-07T15:16:31.071Z\"}}], \"cna\": {\"title\": \"HCI send_sync Dangling Semaphore Reference Re-use\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.9, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:H\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"repo\": \"https://github.com/zephyrproject-rtos/zephyr\", \"vendor\": \"zephyrproject-rtos\", \"product\": \"Zephyr\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\", \"versionType\": \"git\", \"lessThanOrEqual\": \"3.3\"}], \"packageName\": \"Zephyr\", \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-xvvm-8mcm-9cq3\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The bluetooth HCI host layer logic not clearing a global reference to a semaphore after synchronously sending HCI commands may allow a malicious HCI Controller to cause the use of a dangling reference in the host layer, leading to a crash (DoS) or potential RCE on the Host layer.\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The bluetooth HCI host layer logic not clearing a global reference to a semaphore after synchronously sending HCI commands may allow a malicious HCI Controller to cause the use of a dangling reference in the host layer, leading to a crash (DoS) or potential RCE on the Host layer.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\", \"base64\": false}]}], \"providerMetadata\": {\"orgId\": \"e2e69745-5e70-4e92-8431-deb5529a81ad\", \"shortName\": \"zephyr\", \"dateUpdated\": \"2023-07-10T04:37:33.126Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-1901\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-07T15:19:24.502Z\", \"dateReserved\": \"2023-04-05T22:11:42.140Z\", \"assignerOrgId\": \"e2e69745-5e70-4e92-8431-deb5529a81ad\", \"datePublished\": \"2023-07-10T04:37:33.126Z\", \"assignerShortName\": \"zephyr\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…