CVE-2023-2186 (GCVE-0-2023-2186)
Vulnerability from cvelistv5
Published
2023-06-07 06:37
Modified
2025-01-06 20:10
CWE
  • CWE-134 - Use of Externally-Controlled Format String
Summary
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:12:20.659Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-2186",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-06T20:10:12.309182Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-06T20:10:28.548Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SCADA Data Gateway",
          "vendor": "Triangle MicroWorks",
          "versions": [
            {
              "status": "affected",
              "version": "5.01.03"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Sam Quinn"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "On Triangle MicroWorks\u0027 SCADA Data Gateway version \u0026lt;= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor.  Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution."
            }
          ],
          "value": "On Triangle MicroWorks\u0027 SCADA Data Gateway version \u003c= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor.  Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-125",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-125 Flooding"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-134",
              "description": "CWE-134 Use of Externally-Controlled Format String",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-07T06:37:33.280Z",
        "orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
        "shortName": "trellix"
      },
      "references": [
        {
          "url": "https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
    "assignerShortName": "trellix",
    "cveId": "CVE-2023-2186",
    "datePublished": "2023-06-07T06:37:33.280Z",
    "dateReserved": "2023-04-19T15:35:06.060Z",
    "dateUpdated": "2025-01-06T20:10:28.548Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-2186\",\"sourceIdentifier\":\"trellixpsirt@trellix.com\",\"published\":\"2023-06-07T07:15:08.490\",\"lastModified\":\"2024-11-21T07:58:06.300\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"On Triangle MicroWorks\u0027 SCADA Data Gateway version \u003c= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor.  Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-134\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-134\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.01.03\",\"matchCriteriaId\":\"A763593D-AA02-4DF7-9D24-A88EB254594D\"}]}]}],\"references\":[{\"url\":\"https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html\",\"source\":\"trellixpsirt@trellix.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T06:12:20.659Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-2186\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-06T20:10:12.309182Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-06T20:10:21.616Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Sam Quinn\"}], \"impacts\": [{\"capecId\": \"CAPEC-125\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-125 Flooding\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Triangle MicroWorks\", \"product\": \"SCADA Data Gateway\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.01.03\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"On Triangle MicroWorks\u0027 SCADA Data Gateway version \u003c= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor.  Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"On Triangle MicroWorks\u0027 SCADA Data Gateway version \u0026lt;= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor.  Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-134\", \"description\": \"CWE-134 Use of Externally-Controlled Format String\"}]}], \"providerMetadata\": {\"orgId\": \"01626437-bf8f-4d1c-912a-893b5eb04808\", \"shortName\": \"trellix\", \"dateUpdated\": \"2023-06-07T06:37:33.280Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-2186\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-06T20:10:28.548Z\", \"dateReserved\": \"2023-04-19T15:35:06.060Z\", \"assignerOrgId\": \"01626437-bf8f-4d1c-912a-893b5eb04808\", \"datePublished\": \"2023-06-07T06:37:33.280Z\", \"assignerShortName\": \"trellix\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…