CVE-2023-32568 (GCVE-0-2023-32568)
Vulnerability from cvelistv5
Published
2023-05-10 00:00
Modified
2025-01-28 15:54
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered in Veritas InfoScale Operations Manager (VIOM) before 7.4.2.800 and 8.x before 8.0.410. The VIOM web application does not validate user-supplied data and appends it to OS commands and internal binaries used by the application. An attacker with root/administrator level privileges can leverage this to read sensitive data stored on the servers, modify data or server configuration, and delete data or application configuration.
References
► | URL | Tags | |
---|---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:18:37.830Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.veritas.com/content/support/en_US/security/VTS23-007" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-32568", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-28T15:52:26.211405Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-28T15:54:14.856Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Veritas InfoScale Operations Manager (VIOM) before 7.4.2.800 and 8.x before 8.0.410. The VIOM web application does not validate user-supplied data and appends it to OS commands and internal binaries used by the application. An attacker with root/administrator level privileges can leverage this to read sensitive data stored on the servers, modify data or server configuration, and delete data or application configuration." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:H/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.veritas.com/content/support/en_US/security/VTS23-007" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-32568", "datePublished": "2023-05-10T00:00:00.000Z", "dateReserved": "2023-05-10T00:00:00.000Z", "dateUpdated": "2025-01-28T15:54:14.856Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-32568\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2023-05-10T05:15:11.990\",\"lastModified\":\"2025-01-28T16:15:35.987\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Veritas InfoScale Operations Manager (VIOM) before 7.4.2.800 and 8.x before 8.0.410. The VIOM web application does not validate user-supplied data and appends it to OS commands and internal binaries used by the application. An attacker with root/administrator level privileges can leverage this to read sensitive data stored on the servers, modify data or server configuration, and delete data or application configuration.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:veritas:infoscale_operations_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.4.2.800\",\"matchCriteriaId\":\"37CC1778-2B2D-472B-B426-0B69AB2C3DF7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:veritas:infoscale_operations_manager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0.0\",\"versionEndExcluding\":\"8.0.410\",\"matchCriteriaId\":\"266293F1-635B-4EA1-9CF7-984B4A5F0B2B\"}]}]}],\"references\":[{\"url\":\"https://www.veritas.com/content/support/en_US/security/VTS23-007\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.veritas.com/content/support/en_US/security/VTS23-007\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"cna\": {\"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2023-05-10T00:00:00.000Z\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An issue was discovered in Veritas InfoScale Operations Manager (VIOM) before 7.4.2.800 and 8.x before 8.0.410. The VIOM web application does not validate user-supplied data and appends it to OS commands and internal binaries used by the application. An attacker with root/administrator level privileges can leverage this to read sensitive data stored on the servers, modify data or server configuration, and delete data or application configuration.\"}], \"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"version\": \"n/a\", \"status\": \"affected\"}]}], \"references\": [{\"url\": \"https://www.veritas.com/content/support/en_US/security/VTS23-007\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:H/S:U/UI:N\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\"}}], \"problemTypes\": [{\"descriptions\": [{\"type\": \"text\", \"lang\": \"en\", \"description\": \"n/a\"}]}]}, \"adp\": [{\"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T15:18:37.830Z\"}, \"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.veritas.com/content/support/en_US/security/VTS23-007\", \"tags\": [\"x_transferred\"]}]}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-32568\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-28T15:52:26.211405Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-28T15:53:25.004Z\"}}]}", "cveMetadata": "{\"state\": \"PUBLISHED\", \"cveId\": \"CVE-2023-32568\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"assignerShortName\": \"mitre\", \"dateUpdated\": \"2025-01-28T15:54:14.856Z\", \"dateReserved\": \"2023-05-10T00:00:00.000Z\", \"datePublished\": \"2023-05-10T00:00:00.000Z\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…