CVE-2023-39468 (GCVE-0-2023-39468)
Vulnerability from cvelistv5
Published
2024-05-03 01:59
Modified
2024-08-02 18:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-749 - Exposed Dangerous Method or Function
Summary
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.
The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Triangle MicroWorks | SCADA Data Gateway |
Version: 5.1.3.20324 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scada_data_gateway", "vendor": "trianglemicroworks", "versions": [ { "status": "affected", "version": "5.1.3.20324" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-39468", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-08T17:19:46.064913Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:27:09.598Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T18:10:20.697Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "ZDI-23-1036", "tags": [ "x_research-advisory", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/" }, { "name": "vendor-provided URL", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SCADA Data Gateway", "vendor": "Triangle MicroWorks", "versions": [ { "status": "affected", "version": "5.1.3.20324" } ] } ], "dateAssigned": "2023-08-02T16:44:31.433-05:00", "datePublic": "2023-08-04T13:44:48.544-05:00", "descriptions": [ { "lang": "en", "value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799." } ], "metrics": [ { "cvssV3_0": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-749", "description": "CWE-749: Exposed Dangerous Method or Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-03T01:59:30.325Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-23-1036", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/" }, { "name": "vendor-provided URL", "tags": [ "vendor-advisory" ], "url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new" } ], "source": { "lang": "en", "value": "Uri Katz of Claroty Team82" }, "title": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2023-39468", "datePublished": "2024-05-03T01:59:30.325Z", "dateReserved": "2023-08-02T21:37:23.123Z", "dateUpdated": "2024-08-02T18:10:20.697Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-39468\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2024-05-03T03:15:12.563\",\"lastModified\":\"2025-06-17T21:02:53.483\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.\\n\\nThe specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.\"},{\"lang\":\"es\",\"value\":\"Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo de funci\u00f3n peligrosa expuesta. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe en el manejo del par\u00e1metro DbasSectorFileToExecuteOnReset. El problema se debe a una funci\u00f3n peligrosa expuesta. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de SYSTEM. Era ZDI-CAN-20799.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-749\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3\"}]}]}],\"references\":[{\"url\":\"https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Release Notes\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-23-1036/\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Release Notes\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-23-1036/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-23-1036/\", \"name\": \"ZDI-23-1036\", \"tags\": [\"x_research-advisory\", \"x_transferred\"]}, {\"url\": \"https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new\", \"name\": \"vendor-provided URL\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T18:10:20.697Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-39468\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-08T17:19:46.064913Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*\"], \"vendor\": \"trianglemicroworks\", \"product\": \"scada_data_gateway\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.1.3.20324\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-08T17:19:43.615Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Uri Katz of Claroty Team82\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"Triangle MicroWorks\", \"product\": \"SCADA Data Gateway\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.1.3.20324\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2023-08-04T13:44:48.544-05:00\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-23-1036/\", \"name\": \"ZDI-23-1036\", \"tags\": [\"x_research-advisory\"]}, {\"url\": \"https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new\", \"name\": \"vendor-provided URL\", \"tags\": [\"vendor-advisory\"]}], \"dateAssigned\": \"2023-08-02T16:44:31.433-05:00\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.\\n\\nThe specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-749\", \"description\": \"CWE-749: Exposed Dangerous Method or Function\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2024-05-03T01:59:30.325Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2023-39468\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T18:10:20.697Z\", \"dateReserved\": \"2023-08-02T21:37:23.123Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2024-05-03T01:59:30.325Z\", \"assignerShortName\": \"zdi\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…