CVE-2024-0840 (GCVE-0-2024-0840)
Vulnerability from cvelistv5
Published
2024-04-29 18:42
Modified
2024-08-01 18:18
CWE
  • CWE-141 - Improper Neutralization of Parameter/Argument Delimiters
Summary
The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.
Impacted products
Vendor Product Version
Grandstream UCM Series Version: 0   < <1.0.20.52
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ucm6202_firmware",
            "vendor": "grandstream",
            "versions": [
              {
                "lessThan": "1.0.20.52",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ucm6204_firmware",
            "vendor": "grandstream",
            "versions": [
              {
                "lessThan": "1.0.20.52",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ucm6208_firmware",
            "vendor": "grandstream",
            "versions": [
              {
                "lessThan": "1.0.20.52",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:grandstream:ucm6510_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ucm6510_firmware",
            "vendor": "grandstream",
            "versions": [
              {
                "lessThan": "1.0.20.52",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0840",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-01T19:17:53.854809Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T13:09:24.386Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:18:18.719Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://vulncheck.com/advisories/grand-stream-param-injection"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "UCM Series",
          "vendor": "Grandstream",
          "versions": [
            {
              "lessThan": "\u003c1.0.20.52",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jacob Baines (VulnCheck)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\u003cbr\u003e"
            }
          ],
          "value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-137",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-137 Parameter Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-141",
              "description": "CWE-141 Improper Neutralization of Parameter/Argument Delimiters",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-29T18:42:57.112Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "url": "https://vulncheck.com/advisories/grand-stream-param-injection"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "timeline": [
        {
          "lang": "en",
          "time": "2024-01-25T17:00:00.000Z",
          "value": "VulnCheck reports the vulnerability to Grandstream"
        },
        {
          "lang": "en",
          "time": "2024-01-26T02:00:00.000Z",
          "value": "Grandstream acknowledges receipt"
        },
        {
          "lang": "en",
          "time": "2024-02-08T04:42:00.000Z",
          "value": "Grandstream shares a patch build"
        },
        {
          "lang": "en",
          "time": "2024-04-26T04:11:00.000Z",
          "value": "Grandstream releases 1.0.20.52"
        }
      ],
      "title": "Grandstream UCM Series IP PBX HTTP Parameter Injection",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2024-0840",
    "datePublished": "2024-04-29T18:42:57.112Z",
    "dateReserved": "2024-01-23T21:10:19.364Z",
    "dateUpdated": "2024-08-01T18:18:18.719Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-0840\",\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"published\":\"2024-04-29T19:15:19.730\",\"lastModified\":\"2024-11-21T08:47:29.257\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\\n\"},{\"lang\":\"es\",\"value\":\"La central IP Grandstream UCM Series anterior a la versi\u00f3n de firmware 1.0.20.52 se ve afectada por una vulnerabilidad de inyecci\u00f3n de par\u00e1metros en la interfaz HTTP. Un atacante remoto y autenticado puede ejecutar c\u00f3digo arbitrario enviando una solicitud HTTP manipulada. La autenticaci\u00f3n puede ser posible utilizando un usuario y una contrase\u00f1a predeterminados. Los modelos afectados son UCM6202, UCM6204, UCM6208 y UCM6510.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-141\"}]}],\"references\":[{\"url\":\"https://vulncheck.com/advisories/grand-stream-param-injection\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://vulncheck.com/advisories/grand-stream-param-injection\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vulncheck.com/advisories/grand-stream-param-injection\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T18:18:18.719Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-0840\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-01T19:17:53.854809Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"grandstream\", \"product\": \"ucm6202_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.20.52\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"grandstream\", \"product\": \"ucm6204_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.20.52\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"grandstream\", \"product\": \"ucm6208_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.20.52\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:grandstream:ucm6510_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"grandstream\", \"product\": \"ucm6510_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.20.52\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-01T19:13:22.175Z\"}}], \"cna\": {\"title\": \"Grandstream UCM Series IP PBX HTTP Parameter Injection\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Jacob Baines (VulnCheck)\"}], \"impacts\": [{\"capecId\": \"CAPEC-137\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-137 Parameter Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Grandstream\", \"product\": \"UCM Series\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"\u003c1.0.20.52\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-01-25T17:00:00.000Z\", \"value\": \"VulnCheck reports the vulnerability to Grandstream\"}, {\"lang\": \"en\", \"time\": \"2024-01-26T02:00:00.000Z\", \"value\": \"Grandstream acknowledges receipt\"}, {\"lang\": \"en\", \"time\": \"2024-02-08T04:42:00.000Z\", \"value\": \"Grandstream shares a patch build\"}, {\"lang\": \"en\", \"time\": \"2024-04-26T04:11:00.000Z\", \"value\": \"Grandstream releases 1.0.20.52\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\u003cbr\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://vulncheck.com/advisories/grand-stream-param-injection\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-141\", \"description\": \"CWE-141 Improper Neutralization of Parameter/Argument Delimiters\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2024-04-29T18:42:57.112Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-0840\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T18:18:18.719Z\", \"dateReserved\": \"2024-01-23T21:10:19.364Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2024-04-29T18:42:57.112Z\", \"assignerShortName\": \"VulnCheck\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…