CVE-2024-32282 (GCVE-0-2024-32282)
Vulnerability from cvelistv5
Published
2024-04-17 00:00
Modified
2024-08-02 02:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1202_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.2.0.14\\(408\\)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-32282", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-16T14:30:46.381758Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-16T14:36:12.315Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:06:44.042Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexecommand_cmdi.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T13:16:19.702212", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexecommand_cmdi.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-32282", "datePublished": "2024-04-17T00:00:00", "dateReserved": "2024-04-12T00:00:00", "dateUpdated": "2024-08-02T02:06:44.042Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-32282\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2024-04-17T14:15:08.627\",\"lastModified\":\"2025-04-09T14:20:58.563\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Tenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.\"},{\"lang\":\"es\",\"value\":\"El firmware Tenda FH1202 v1.2.0.14(408) contiene una vulnerabilidad de inyecci\u00f3n de comandos en la funci\u00f3n formexeCommand a trav\u00e9s del par\u00e1metro cmdinput.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\\\(408\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B9FD9D0A-39F4-4AD8-AEE0-71C9E77D2799\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A632A11-60A0-457C-A039-BED32F83BD52\"}]}]}],\"references\":[{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexecommand_cmdi.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexecommand_cmdi.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-32282\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-16T14:30:46.381758Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\\\(408\\\\):*:*:*:*:*:*:*\"], \"vendor\": \"tenda\", \"product\": \"fh1202_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.2.0.14\\\\(408\\\\)\"}], \"defaultStatus\": \"unknown\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-16T14:34:34.355Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexecommand_cmdi.md\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Tenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2024-04-17T13:16:19.702212\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-32282\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-07-16T14:36:12.315Z\", \"dateReserved\": \"2024-04-12T00:00:00\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2024-04-17T00:00:00\", \"assignerShortName\": \"mitre\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…