CVE-2025-23170 (GCVE-0-2025-23170)
Vulnerability from cvelistv5
Published
2025-06-18 23:30
Modified
2025-06-23 16:05
Summary
The Versa Director SD-WAN orchestration platform includes functionality to initiate SSH sessions to remote CPEs and the Director shell via Shell-In-A-Box. The underlying Python script, shell-connect.py, is vulnerable to command injection through the user argument. This allows an attacker to execute arbitrary commands on the system. Exploitation Status: Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: There are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions.
Impacted products
Vendor Product Version
Versa Director Version: 21.2.2    21.2.2
Version: 21.2.3    21.2.3
Version: 22.1.1    22.1.1
Version: 22.1.2    22.1.2
Version: 22.1.3    22.1.3
Version: 22.1.4    22.1.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23170",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-23T15:45:59.393412Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-23T16:05:43.363Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Director",
          "vendor": "Versa",
          "versions": [
            {
              "lessThanOrEqual": "21.2.2",
              "status": "affected",
              "version": "21.2.2",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "21.2.3",
              "status": "affected",
              "version": "21.2.3",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "22.1.1",
              "status": "affected",
              "version": "22.1.1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "22.1.2",
              "status": "affected",
              "version": "22.1.2",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "22.1.3",
              "status": "affected",
              "version": "22.1.3",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "22.1.4",
              "status": "affected",
              "version": "22.1.4",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Versa Director SD-WAN orchestration platform includes functionality to initiate SSH sessions to remote CPEs and the Director shell via Shell-In-A-Box. The underlying Python script, shell-connect.py, is vulnerable to command injection through the user argument. This allows an attacker to execute arbitrary commands on the system. \r\n\r\nExploitation Status: \r\n\r\nVersa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers.  \r\n\r\nWorkarounds or Mitigation: \r\n\r\nThere are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-18T23:30:49.238Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "url": "https://security-portal.versa-networks.com/emailbulletins/68526bc7dc94d6b9f2faf717"
        },
        {
          "url": "https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4"
        },
        {
          "url": "https://support.versa-networks.com/support/solutions/articles/23000026033-release-22-1-3"
        },
        {
          "url": "https://support.versa-networks.com/support/solutions/articles/23000025680-release-22-1-2"
        },
        {
          "url": "https://support.versa-networks.com/support/solutions/articles/23000024323-release-21-2-3"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2025-23170",
    "datePublished": "2025-06-18T23:30:49.238Z",
    "dateReserved": "2025-01-12T01:00:00.649Z",
    "dateUpdated": "2025-06-23T16:05:43.363Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-23170\",\"sourceIdentifier\":\"support@hackerone.com\",\"published\":\"2025-06-19T00:15:21.620\",\"lastModified\":\"2025-06-23T20:16:59.783\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Versa Director SD-WAN orchestration platform includes functionality to initiate SSH sessions to remote CPEs and the Director shell via Shell-In-A-Box. The underlying Python script, shell-connect.py, is vulnerable to command injection through the user argument. This allows an attacker to execute arbitrary commands on the system. \\r\\n\\r\\nExploitation Status: \\r\\n\\r\\nVersa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers.  \\r\\n\\r\\nWorkarounds or Mitigation: \\r\\n\\r\\nThere are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions.\"},{\"lang\":\"es\",\"value\":\"La plataforma de orquestaci\u00f3n Versa Director SD-WAN incluye la funcionalidad para iniciar sesiones SSH con CPE remotos y el shell de Director mediante Shell-In-A-Box. El script de Python subyacente, shell-connect.py, es vulnerable a la inyecci\u00f3n de comandos mediante el argumento de usuario. Esto permite a un atacante ejecutar comandos arbitrarios en el sistema. Estado de explotaci\u00f3n: Versa Networks no tiene constancia de ning\u00fan caso reportado de explotaci\u00f3n de esta vulnerabilidad. Investigadores de seguridad externos han divulgado una prueba de concepto para esta vulnerabilidad. Soluciones alternativas o mitigaci\u00f3n: No existen soluciones alternativas para deshabilitar la opci\u00f3n de la interfaz gr\u00e1fica de usuario. Versa recomienda actualizar Director a una de las versiones de software corregidas.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"support@hackerone.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"references\":[{\"url\":\"https://security-portal.versa-networks.com/emailbulletins/68526bc7dc94d6b9f2faf717\",\"source\":\"support@hackerone.com\"},{\"url\":\"https://support.versa-networks.com/support/solutions/articles/23000024323-release-21-2-3\",\"source\":\"support@hackerone.com\"},{\"url\":\"https://support.versa-networks.com/support/solutions/articles/23000025680-release-22-1-2\",\"source\":\"support@hackerone.com\"},{\"url\":\"https://support.versa-networks.com/support/solutions/articles/23000026033-release-22-1-3\",\"source\":\"support@hackerone.com\"},{\"url\":\"https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4\",\"source\":\"support@hackerone.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-23170\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-23T15:45:59.393412Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-23T15:46:00.528Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.7, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"Versa\", \"product\": \"Director\", \"versions\": [{\"status\": \"affected\", \"version\": \"21.2.2\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"21.2.2\"}, {\"status\": \"affected\", \"version\": \"21.2.3\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"21.2.3\"}, {\"status\": \"affected\", \"version\": \"22.1.1\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"22.1.1\"}, {\"status\": \"affected\", \"version\": \"22.1.2\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"22.1.2\"}, {\"status\": \"affected\", \"version\": \"22.1.3\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"22.1.3\"}, {\"status\": \"affected\", \"version\": \"22.1.4\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"22.1.4\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://security-portal.versa-networks.com/emailbulletins/68526bc7dc94d6b9f2faf717\"}, {\"url\": \"https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4\"}, {\"url\": \"https://support.versa-networks.com/support/solutions/articles/23000026033-release-22-1-3\"}, {\"url\": \"https://support.versa-networks.com/support/solutions/articles/23000025680-release-22-1-2\"}, {\"url\": \"https://support.versa-networks.com/support/solutions/articles/23000024323-release-21-2-3\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"The Versa Director SD-WAN orchestration platform includes functionality to initiate SSH sessions to remote CPEs and the Director shell via Shell-In-A-Box. The underlying Python script, shell-connect.py, is vulnerable to command injection through the user argument. This allows an attacker to execute arbitrary commands on the system. \\r\\n\\r\\nExploitation Status: \\r\\n\\r\\nVersa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers.  \\r\\n\\r\\nWorkarounds or Mitigation: \\r\\n\\r\\nThere are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions.\"}], \"providerMetadata\": {\"orgId\": \"36234546-b8fa-4601-9d6f-f4e334aa8ea1\", \"shortName\": \"hackerone\", \"dateUpdated\": \"2025-06-18T23:30:49.238Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-23170\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-23T16:05:43.363Z\", \"dateReserved\": \"2025-01-12T01:00:00.649Z\", \"assignerOrgId\": \"36234546-b8fa-4601-9d6f-f4e334aa8ea1\", \"datePublished\": \"2025-06-18T23:30:49.238Z\", \"assignerShortName\": \"hackerone\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…