CVE-2025-27688 (GCVE-0-2025-27688)
Vulnerability from cvelistv5
Published
2025-03-18 15:55
Modified
2025-03-19 03:55
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Summary
Dell ThinOS 2408 and prior, contains an improper permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
References
► | URL | Tags | |
---|---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Wyse Proprietary OS (Modern ThinOS) |
Version: N/A ≤ |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-27688", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-18T00:00:00+00:00", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-19T03:55:50.783Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Wyse Proprietary OS (Modern ThinOS)", "vendor": "Dell", "versions": [ { "lessThan": "ThinOS 2502", "status": "affected", "version": "N/A", "versionType": "semver" } ] } ], "datePublic": "2025-03-18T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dell ThinOS 2408 and prior, contains an improper permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.\u003cbr\u003e" } ], "value": "Dell ThinOS 2408 and prior, contains an improper permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732: Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-18T15:55:44.470Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000289886/dsa-2025-107" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2025-27688", "datePublished": "2025-03-18T15:55:44.470Z", "dateReserved": "2025-03-05T07:33:28.315Z", "dateUpdated": "2025-03-19T03:55:50.783Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-27688\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2025-03-18T16:15:27.980\",\"lastModified\":\"2025-07-01T15:08:57.517\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell ThinOS 2408 and prior, contains an improper permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.\"},{\"lang\":\"es\",\"value\":\"Dell ThinOS 2408 y versiones anteriores presentan una vulnerabilidad de permisos inadecuados. Un atacante con pocos privilegios y acceso local podr\u00eda explotar esta vulnerabilidad, lo que conllevar\u00eda una elevaci\u00f3n de privilegios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:thinos:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2408\",\"matchCriteriaId\":\"4548306E-F9EB-401E-A5F2-628BC422897E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:latitude_3420:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FB6E60F-F100-42BF-BC38-A38620EF8D2C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:latitude_3440:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31C78A9B-65B4-4213-9A96-4E57CFA5B195\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:latitude_5440:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"84EC8EA3-A91D-4D3B-B1A5-D650A526CAAE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:latitude_5450:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3DAF60D4-BDA2-43ED-802D-CE3ACB548693\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:optiplex_3000_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C4B0B6B-7740-46D0-9FE0-3AFF8D9B4DDA\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:optiplex_5400_all-in-one:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D08E685B-A29C-482E-989C-083B83E7C5CE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:optiplex_7410_all-in-one:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"802CD46E-86A4-4C9A-92DF-3297950D64B3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:optiplex_7420_all-in-one:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E03807D5-B923-4CA3-A53E-C616846C9C6B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:wyse_5070_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1664E2E-057D-4A8F-B8FC-73EC25D48DBC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:wyse_5470_all-in-one_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3929B7A4-D181-4258-8722-57A751DB4CCC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:wyse_5470_mobile_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D9B6263-FF2F-428D-971B-48029951E62B\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000289886/dsa-2025-107\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-27688\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-03-18T16:07:36.894468Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-03-18T16:07:44.096Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"Wyse Proprietary OS (Modern ThinOS)\", \"versions\": [{\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"ThinOS 2502\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-03-18T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000289886/dsa-2025-107\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell ThinOS 2408 and prior, contains an improper permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell ThinOS 2408 and prior, contains an improper permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-732\", \"description\": \"CWE-732: Incorrect Permission Assignment for Critical Resource\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2025-03-18T15:55:44.470Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-27688\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-19T03:55:50.783Z\", \"dateReserved\": \"2025-03-05T07:33:28.315Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2025-03-18T15:55:44.470Z\", \"assignerShortName\": \"dell\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…