CVE-2025-31710 (GCVE-0-2025-31710)
Vulnerability from cvelistv5
Published
2025-06-03 05:50
Modified
2025-06-03 15:19
CWE
  • cwe-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Summary
In engineermode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31710",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-03T15:17:49.246871Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-03T15:19:39.406Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SC9863A/T606/T612/T616/T750/T765/T760/T770/T820/S8000/T8300/T9300",
          "vendor": "Unisoc (Shanghai) Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "Android13/Android14/Android15"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In engineermode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "cwe-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-03T05:50:51.239Z",
        "orgId": "63f92e9c-2193-4c24-98a9-93640392c3d3",
        "shortName": "Unisoc"
      },
      "references": [
        {
          "url": "https://www.unisoc.com/en_us/secy/announcementDetail/1929773763314909186"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "63f92e9c-2193-4c24-98a9-93640392c3d3",
    "assignerShortName": "Unisoc",
    "cveId": "CVE-2025-31710",
    "datePublished": "2025-06-03T05:50:51.239Z",
    "dateReserved": "2025-04-01T08:28:54.048Z",
    "dateUpdated": "2025-06-03T15:19:39.406Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-31710\",\"sourceIdentifier\":\"security@unisoc.com\",\"published\":\"2025-06-03T06:15:27.310\",\"lastModified\":\"2025-06-10T15:15:23.847\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In engineermode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed.\"},{\"lang\":\"es\",\"value\":\"En el servicio en modo ingeniero, existe una posible inyecci\u00f3n de comandos debido a una validaci\u00f3n de entrada incorrecta. Esto podr\u00eda provocar una escalada local de privilegios sin necesidad de permisos de ejecuci\u00f3n adicionales.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security@unisoc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.5,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.5,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:google:android:13.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"879FFD0C-9B38-4CAA-B057-1086D794D469\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:google:android:14.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2700BCC5-634D-4EC6-AB67-5B678D5F951D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:google:android:15.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8538774C-906D-4B03-A3E7-FA7A55E0DA9E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:s8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FDE05D06-C798-4217-8858-8C5DC2C94751\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:sc9863a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE00DFDE-97DD-4D33-B580-73FEF677C71B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t606:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"905E39DD-7948-40A4-B042-EBB9A9591347\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t612:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"98408A48-561A-49D1-967F-834311742B7F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t616:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"756E5850-CDC7-46C2-BAFC-1E2A359A2709\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B37CC5BC-D87D-497A-B8A1-38718AB4F116\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t760:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D965CCA-C963-49E4-ACF0-2A9F458AF470\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t765:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFCCDED4-7E32-48CB-909D-06001C35E745\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t770:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0FFEF06A-E3E0-486F-89CC-D52FF3F26F0B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t820:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49601008-D3FF-47CC-B961-6FDDFC7A0596\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t8300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC7743D5-B187-48D4-BC77-D8DCDF263166\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:unisoc:t9300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"027BA3F8-B2E3-4D71-977D-E86E8D539269\"}]}]}],\"references\":[{\"url\":\"https://www.unisoc.com/en_us/secy/announcementDetail/1929773763314909186\",\"source\":\"security@unisoc.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-31710\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-03T15:17:49.246871Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-03T15:17:58.911Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 5.9, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Unisoc (Shanghai) Technologies Co., Ltd.\", \"product\": \"SC9863A/T606/T612/T616/T750/T765/T760/T770/T820/S8000/T8300/T9300\", \"versions\": [{\"status\": \"affected\", \"version\": \"Android13/Android14/Android15\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.unisoc.com/en_us/secy/announcementDetail/1929773763314909186\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"In engineermode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"description\": \"cwe-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"63f92e9c-2193-4c24-98a9-93640392c3d3\", \"shortName\": \"Unisoc\", \"dateUpdated\": \"2025-06-03T05:50:51.239Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-31710\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-03T15:19:39.406Z\", \"dateReserved\": \"2025-04-01T08:28:54.048Z\", \"assignerOrgId\": \"63f92e9c-2193-4c24-98a9-93640392c3d3\", \"datePublished\": \"2025-06-03T05:50:51.239Z\", \"assignerShortName\": \"Unisoc\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…