CVE-2025-31715 (GCVE-0-2025-31715)
Vulnerability from cvelistv5
Published
2025-08-18 00:34
Modified
2025-08-18 00:34
Severity ?
VLAI Severity ?
EPSS score ?
Summary
In vowifi service, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Unisoc (Shanghai) Technologies Co., Ltd. | SL8521E/SL8521ET/ SL8541E/UIS8141E/UWS6137/UWS6137E/UWS6151(E)/UWS6152 |
Version: Mocor5/Andorid8.1/Andorid9 |
{ "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "SL8521E/SL8521ET/ SL8541E/UIS8141E/UWS6137/UWS6137E/UWS6151(E)/UWS6152", "vendor": "Unisoc (Shanghai) Technologies Co., Ltd.", "versions": [ { "status": "affected", "version": "Mocor5/Andorid8.1/Andorid9" } ] } ], "descriptions": [ { "lang": "en", "value": "In vowifi service, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-18T00:34:30.378Z", "orgId": "63f92e9c-2193-4c24-98a9-93640392c3d3", "shortName": "Unisoc" }, "references": [ { "url": "https://www.unisoc.com/en_us/secy/announcementDetail/1944933773300793346" } ] } }, "cveMetadata": { "assignerOrgId": "63f92e9c-2193-4c24-98a9-93640392c3d3", "assignerShortName": "Unisoc", "cveId": "CVE-2025-31715", "datePublished": "2025-08-18T00:34:30.378Z", "dateReserved": "2025-04-01T08:30:14.187Z", "dateUpdated": "2025-08-18T00:34:30.378Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-31715\",\"sourceIdentifier\":\"security@unisoc.com\",\"published\":\"2025-08-18T01:15:30.463\",\"lastModified\":\"2025-08-18T01:15:30.463\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In vowifi service, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security@unisoc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"references\":[{\"url\":\"https://www.unisoc.com/en_us/secy/announcementDetail/1944933773300793346\",\"source\":\"security@unisoc.com\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…