CVE-2025-41675 (GCVE-0-2025-41675)
Vulnerability from cvelistv5
Published
2025-07-21 09:29
Modified
2025-07-21 20:36
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
► | MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-41675", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-07-21T15:00:42.591445Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-07-21T20:36:45.460Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "mbNET.mini", "vendor": "MB connect line", "versions": [ { "lessThan": "2.3.3", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "REX 100", "vendor": "Helmholz", "versions": [ { "lessThan": "2.3.3", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\u003cbr\u003e" } ], "value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-21T09:29:57.024Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://certvde.com/de/advisories/VDE-2025-058" } ], "source": { "advisory": "VDE-2025-058, VDE-2025-059", "defect": [ "CERT@VDE#641816", "CERT@VDE#641817" ], "discovery": "UNKNOWN" }, "title": "Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2025-41675", "datePublished": "2025-07-21T09:29:57.024Z", "dateReserved": "2025-04-16T11:17:48.308Z", "dateUpdated": "2025-07-21T20:36:45.460Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-41675\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2025-07-21T10:15:24.530\",\"lastModified\":\"2025-07-22T13:06:07.260\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto con altos privilegios puede ejecutar comandos de sistema arbitrarios a trav\u00e9s de solicitudes GET en el script de comunicaci\u00f3n del servidor en la nube debido a la neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del sistema operativo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://certvde.com/de/advisories/VDE-2025-058\",\"source\":\"info@cert.vde.com\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-41675\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-21T15:00:42.591445Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-21T20:35:41.686Z\"}}], \"cna\": {\"title\": \"Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization\", \"source\": {\"defect\": [\"CERT@VDE#641816\", \"CERT@VDE#641817\"], \"advisory\": \"VDE-2025-058, VDE-2025-059\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"MB connect line\", \"product\": \"mbNET.mini\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0\", \"lessThan\": \"2.3.3\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Helmholz\", \"product\": \"REX 100\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0\", \"lessThan\": \"2.3.3\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://certvde.com/de/advisories/VDE-2025-058\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2025-07-21T09:29:57.024Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-41675\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-21T20:36:45.460Z\", \"dateReserved\": \"2025-04-16T11:17:48.308Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2025-07-21T09:29:57.024Z\", \"assignerShortName\": \"CERTVDE\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…