CVE-2025-50130 (GCVE-0-2025-50130)
Vulnerability from cvelistv5
Published
2025-07-08 12:59
Modified
2025-07-08 13:33
CWE
  • CWE-122 - Heap-based buffer overflow
Summary
A heap-based buffer overflow vulnerability exists in VS6Sim.exe contained in V-SFT and TELLUS provided by FUJI ELECTRIC CO., LTD. Opening V9 files or X1 files specially crafted by an attacker on the affected product may lead to arbitrary code execution.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-50130",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-08T13:33:13.788717Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-08T13:33:54.007Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "V-SFT-6",
          "vendor": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v6.2.5.0 and earlier"
            }
          ]
        },
        {
          "product": "TELLUS",
          "vendor": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "v4.0.20.0 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A heap-based buffer overflow vulnerability exists in VS6Sim.exe contained in V-SFT and TELLUS provided by FUJI ELECTRIC CO., LTD.\r\nOpening V9 files or X1 files specially crafted by an attacker on the affected product may lead to arbitrary code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "Heap-based buffer overflow",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-08T12:59:44.115Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://jvn.jp/en/vu/JVNVU94011267/"
        },
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php"
        },
        {
          "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/Search.php"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2025-50130",
    "datePublished": "2025-07-08T12:59:44.115Z",
    "dateReserved": "2025-06-13T02:38:24.373Z",
    "dateUpdated": "2025-07-08T13:33:54.007Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-50130\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2025-07-08T13:15:33.710\",\"lastModified\":\"2025-07-08T16:18:14.207\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A heap-based buffer overflow vulnerability exists in VS6Sim.exe contained in V-SFT and TELLUS provided by FUJI ELECTRIC CO., LTD.\\r\\nOpening V9 files or X1 files specially crafted by an attacker on the affected product may lead to arbitrary code execution.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de desbordamiento de b\u00fafer en el mont\u00f3n en VS6Sim.exe, incluido en V-SFT y TELLUS, proporcionados por FUJI ELECTRIC CO., LTD. Abrir archivos V9 o X1 especialmente manipulados por un atacante en el producto afectado puede provocar la ejecuci\u00f3n de c\u00f3digo arbitrario.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"vultures@jpcert.or.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"vultures@jpcert.or.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"vultures@jpcert.or.jp\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]}],\"references\":[{\"url\":\"https://jvn.jp/en/vu/JVNVU94011267/\",\"source\":\"vultures@jpcert.or.jp\"},{\"url\":\"https://monitouch.fujielectric.com/site/download-e/03tellus_inf/Search.php\",\"source\":\"vultures@jpcert.or.jp\"},{\"url\":\"https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php\",\"source\":\"vultures@jpcert.or.jp\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-50130\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-08T13:33:13.788717Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-08T13:33:50.357Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\"}, \"scenarios\": [{\"lang\": \"en-US\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.4, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\"}, \"scenarios\": [{\"lang\": \"en-US\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.\", \"product\": \"V-SFT-6\", \"versions\": [{\"status\": \"affected\", \"version\": \"v6.2.5.0 and earlier\"}]}, {\"vendor\": \"FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.\", \"product\": \"TELLUS\", \"versions\": [{\"status\": \"affected\", \"version\": \"v4.0.20.0 and earlier\"}]}], \"references\": [{\"url\": \"https://jvn.jp/en/vu/JVNVU94011267/\"}, {\"url\": \"https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php\"}, {\"url\": \"https://monitouch.fujielectric.com/site/download-e/03tellus_inf/Search.php\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A heap-based buffer overflow vulnerability exists in VS6Sim.exe contained in V-SFT and TELLUS provided by FUJI ELECTRIC CO., LTD.\\r\\nOpening V9 files or X1 files specially crafted by an attacker on the affected product may lead to arbitrary code execution.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en-US\", \"type\": \"CWE\", \"cweId\": \"CWE-122\", \"description\": \"Heap-based buffer overflow\"}]}], \"providerMetadata\": {\"orgId\": \"ede6fdc4-6654-4307-a26d-3331c018e2ce\", \"shortName\": \"jpcert\", \"dateUpdated\": \"2025-07-08T12:59:44.115Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-50130\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-08T13:33:54.007Z\", \"dateReserved\": \"2025-06-13T02:38:24.373Z\", \"assignerOrgId\": \"ede6fdc4-6654-4307-a26d-3331c018e2ce\", \"datePublished\": \"2025-07-08T12:59:44.115Z\", \"assignerShortName\": \"jpcert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…