CVE-2025-5105 (GCVE-0-2025-5105)
Vulnerability from cvelistv5
Published
2025-05-23 12:00
Modified
2025-05-23 13:16
CWE
  • CWE-244 - Improper Clearing of Heap Memory Before Release
Summary
A vulnerability was found in TOZED ZLT W51 up to 1.4.2 and classified as critical. Affected by this issue is some unknown functionality of the component Service Port 7777. The manipulation leads to improper clearing of heap memory before release. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
TOZED ZLT W51 Version: 1.4.0
Version: 1.4.1
Version: 1.4.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5105",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-23T13:13:08.930769Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-23T13:16:21.832Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Service Port 7777"
          ],
          "product": "ZLT W51",
          "vendor": "TOZED",
          "versions": [
            {
              "status": "affected",
              "version": "1.4.0"
            },
            {
              "status": "affected",
              "version": "1.4.1"
            },
            {
              "status": "affected",
              "version": "1.4.2"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Mohamed Maatallah (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOZED ZLT W51 up to 1.4.2 and classified as critical. Affected by this issue is some unknown functionality of the component Service Port 7777. The manipulation leads to improper clearing of heap memory before release. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in TOZED ZLT W51 bis 1.4.2 gefunden. Sie wurde als kritisch eingestuft. Dies betrifft einen unbekannten Teil der Komponente Service Port 7777. Durch die Manipulation mit unbekannten Daten kann eine improper clearing of heap memory before release-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 7.5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-244",
              "description": "Improper Clearing of Heap Memory Before Release",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-23T12:00:06.933Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-310082 | TOZED ZLT W51 Service Port 7777 heap inspection",
          "tags": [
            "vdb-entry",
            "mitigation"
          ],
          "url": "https://vuldb.com/?id.310082"
        },
        {
          "name": "VDB-310082 | CTI Indicators (IOB, IOC)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.310082"
        },
        {
          "name": "Submit #568495 | TOZED ZLT W51 Wifi6 Router (Ooredoo) Firmware version  1.4.2 Information Disclosure",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.568495"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/Zephkek/LeakyTozed"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Zephkek/LeakyTozed#41-proof-of-concept"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-05-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-05-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-05-23T08:26:05.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOZED ZLT W51 Service Port 7777 heap inspection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5105",
    "datePublished": "2025-05-23T12:00:06.933Z",
    "dateReserved": "2025-05-23T06:20:10.379Z",
    "dateUpdated": "2025-05-23T13:16:21.832Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-5105\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-05-23T12:15:19.423\",\"lastModified\":\"2025-05-23T15:54:42.643\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was found in TOZED ZLT W51 up to 1.4.2 and classified as critical. Affected by this issue is some unknown functionality of the component Service Port 7777. The manipulation leads to improper clearing of heap memory before release. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Se encontr\u00f3 una vulnerabilidad en TOZED ZLT W51 hasta la versi\u00f3n 1.4.2, clasificada como cr\u00edtica. Este problema afecta a una funcionalidad desconocida del componente Service Port 7777. La manipulaci\u00f3n provoca un borrado incorrecto de la memoria del mont\u00f3n antes de su lanzamiento. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n sobre esta divulgaci\u00f3n, pero no respondi\u00f3.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-244\"}]}],\"references\":[{\"url\":\"https://github.com/Zephkek/LeakyTozed\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://github.com/Zephkek/LeakyTozed#41-proof-of-concept\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?ctiid.310082\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?id.310082\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?submit.568495\",\"source\":\"cna@vuldb.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5105\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-23T13:13:08.930769Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-23T13:16:17.331Z\"}}], \"cna\": {\"title\": \"TOZED ZLT W51 Service Port 7777 heap inspection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"Mohamed Maatallah (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 6.9, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 7.5, \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\"}}], \"affected\": [{\"vendor\": \"TOZED\", \"modules\": [\"Service Port 7777\"], \"product\": \"ZLT W51\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.4.0\"}, {\"status\": \"affected\", \"version\": \"1.4.1\"}, {\"status\": \"affected\", \"version\": \"1.4.2\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-05-23T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-05-23T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-05-23T08:26:05.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.310082\", \"name\": \"VDB-310082 | TOZED ZLT W51 Service Port 7777 heap inspection\", \"tags\": [\"vdb-entry\", \"mitigation\"]}, {\"url\": \"https://vuldb.com/?ctiid.310082\", \"name\": \"VDB-310082 | CTI Indicators (IOB, IOC)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.568495\", \"name\": \"Submit #568495 | TOZED ZLT W51 Wifi6 Router (Ooredoo) Firmware version  1.4.2 Information Disclosure\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/Zephkek/LeakyTozed\", \"tags\": [\"related\"]}, {\"url\": \"https://github.com/Zephkek/LeakyTozed#41-proof-of-concept\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in TOZED ZLT W51 up to 1.4.2 and classified as critical. Affected by this issue is some unknown functionality of the component Service Port 7777. The manipulation leads to improper clearing of heap memory before release. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"Eine Schwachstelle wurde in TOZED ZLT W51 bis 1.4.2 gefunden. Sie wurde als kritisch eingestuft. Dies betrifft einen unbekannten Teil der Komponente Service Port 7777. Durch die Manipulation mit unbekannten Daten kann eine improper clearing of heap memory before release-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk passieren. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-244\", \"description\": \"Improper Clearing of Heap Memory Before Release\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-05-23T12:00:06.933Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-5105\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-23T13:16:21.832Z\", \"dateReserved\": \"2025-05-23T06:20:10.379Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-05-23T12:00:06.933Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…