fkie_cve-2010-2772
Vulnerability from fkie_nvd
Published
2010-07-22 05:43
Modified
2025-04-11 00:51
Severity ?
Summary
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc | 6.2 | |
siemens | simatic_wincc | 7.0 | |
siemens | simatic_pcs_7 | 6.0 | |
siemens | simatic_pcs_7 | 6.1 | |
siemens | simatic_pcs_7 | 7.0 | |
siemens | simatic_pcs_7 | 7.0 | |
siemens | simatic_pcs_7 | 7.1 | |
siemens | simatic_pcs_7 | 7.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc:6.2:*:*:*:*:*:*:*", "matchCriteriaId": "9BD0EB37-CFA4-49AE-A952-1A4E2E2EE998", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*", "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:6.0:*:*:*:*:*:*:*", "matchCriteriaId": "963E0E16-2A77-45C8-8708-46B4158C40D0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:6.1:*:*:*:*:*:*:*", "matchCriteriaId": "2C026414-5F0C-48E7-A93D-12E2E33AB6CB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:-:*:*:*:*:*:*", "matchCriteriaId": "BD419DE7-CB43-42E7-ACCC-82EA4913E8D2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "036B082A-1B48-4BA0-A915-4344C70E430D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:*:*:*:*:*:*:*", "matchCriteriaId": "D7885AE5-023B-45BC-8E4A-CF796B5757C2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*", "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568." }, { "lang": "es", "value": "Siemens Simatic WinCC y sistemas PCS 7 SCADA utiliza una contrase\u00f1a no modificable en el c\u00f3digo, lo cual permite a usuarios locales acceder a una base de datos interna (back-end) y obtener privilegios, como se demuestra en julio de 2010 por el gusano Stuxnet, una vulnerabilidad diferente de CVE-2010-2568." } ], "id": "CVE-2010-2772", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.9, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 10.0, "obtainAllPrivilege": true, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2010-07-22T05:43:58.250", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01" }, { "source": "cve@mitre.org", "tags": [ "Press/Media Coverage" ], "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725" }, { "source": "cve@mitre.org", "tags": [ "Press/Media Coverage" ], "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr" }, { "source": "cve@mitre.org", "tags": [ "Press/Media Coverage" ], "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/" }, { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "http://secunia.com/advisories/40682" }, { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c" }, { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127\u002616127\u0026Language=en\u0026PageIndex=1" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "http://www.f-secure.com/weblog/archives/00001987.html" }, { "source": "cve@mitre.org", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx" }, { "source": "cve@mitre.org", "tags": [ "Broken Link", "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/41753" }, { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "http://www.vupen.com/english/advisories/2010/1893" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Issue Tracking" ], "url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22" }, { "source": "cve@mitre.org", "tags": [ "Press/Media Coverage", "Third Party Advisory" ], "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Press/Media Coverage" ], "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Press/Media Coverage" ], "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Press/Media Coverage" ], "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "http://secunia.com/advisories/40682" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable" ], "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127\u002616127\u0026Language=en\u0026PageIndex=1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "http://www.f-secure.com/weblog/archives/00001987.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/41753" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "http://www.vupen.com/english/advisories/2010/1893" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Issue Tracking" ], "url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Press/Media Coverage", "Third Party Advisory" ], "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.