Summary
A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?id.12789 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.12789 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
telecomsoftware | samwin_agent | 5.01.19.06 | |
telecomsoftware | samwin_contact_center | 5.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:telecomsoftware:samwin_agent:5.01.19.06:*:*:*:*:*:*:*", "matchCriteriaId": "277DED3E-2806-4FDC-95ED-FC3166AAE8DE", "vulnerable": true }, { "criteria": "cpe:2.3:a:telecomsoftware:samwin_contact_center:5.1:*:*:*:*:*:*:*", "matchCriteriaId": "E5873B41-8E61-4AFB-842A-903ACF22B5AC", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component." }, { "lang": "es", "value": "Se ha encontrado una vulnerabilidad clasificada como cr\u00edtica en Telecommunication Software SAMwin Contact Center Suite versi\u00f3n 5.1. Afecta a la funci\u00f3n getCurrentDBVersion de la biblioteca SAMwinLIBVB.dll del manejador de la base de datos. La manipulaci\u00f3n conlleva a una inyecci\u00f3n sql. La explotaci\u00f3n ha sido divulgada al p\u00fablico y puede ser usado. La actualizaci\u00f3n a versi\u00f3n 6.2 puede abordar este problema. Es recomendado actualizar el componente afectado" } ], "id": "CVE-2013-10003", "lastModified": "2024-11-21T01:48:38.493", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 2.5, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-05-24T16:15:07.437", "references": [ { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.12789" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.12789" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-89" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-89" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…