fkie_cve-2015-1356
Vulnerability from fkie_nvd
Published
2015-02-18 02:59
Modified
2025-04-12 10:46
Severity ?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_step_7 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E429A7F-72D9-4491-9946-3D41E285FA88", "versionEndIncluding": "13.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 determines a user\u0027s privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file." }, { "lang": "es", "value": "Siemens SIMATIC STEP 7 (TIA Portal) anterior a 13 SP1 determina los privilegios de un usuario bas\u00e1ndose en campos de ficheros de proyectos que no tienen la protecci\u00f3n de integridad, lo que permite a atacantes remotos establecer una autorizaci\u00f3n arbitraria a trav\u00e9s de un fichero modificado." } ], "id": "CVE-2015-1356", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2015-02-18T02:59:06.703", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-234789.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-234789.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-264" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…