fkie_cve-2017-6028
Vulnerability from fkie_nvd
Published
2017-06-30 03:29
Modified
2025-04-20 01:37
Severity ?
Summary
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/97254 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/97254 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | modicon_m241_firmware | * | |
schneider-electric | modicon_m241 | - | |
schneider-electric | modicon_m251_firmware | * | |
schneider-electric | modicon_m251 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CA3FF3A-9145-4DAD-BAD6-D55C97E182AA", "versionEndIncluding": "4.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*", "matchCriteriaId": "4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FDB0710-FB7F-4346-9EEC-4C75ECEA0A1E", "versionEndIncluding": "4.0.3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*", "matchCriteriaId": "B8E03A25-B0B6-4BA2-80BC-52C16A6837E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application." }, { "lang": "es", "value": "Un problema de credenciales protegidas insuficientemente fue detectado en PLCs Modicon M241, y Modicon M251 de Schneider Electric, en todas las versiones de firmware. Las credenciales de inicio de sesi\u00f3n se env\u00edan por medio de la red con codificaci\u00f3n Base64 dej\u00e1ndolas susceptibles a ser espiadas. Las credenciales espiadas se podr\u00edan usar para iniciar sesi\u00f3n en la aplicaci\u00f3n web." } ], "id": "CVE-2017-6028", "lastModified": "2025-04-20T01:37:25.860", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-06-30T03:29:00.360", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/97254" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/97254" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…