Summary
Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02 | ||
cve@mitre.org | http://www.securityfocus.com/bid/97523 | Third Party Advisory, VDB Entry | |
cve@mitre.org | https://os-s.net/advisories/OSS-2017-01.pdf | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02 | ||
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/97523 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://os-s.net/advisories/OSS-2017-01.pdf | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | modicon_tm221ce16r_firmware | 1.3.3.3 | |
schneider-electric | modicon_tm221ce16r | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_tm221ce16r_firmware:1.3.3.3:*:*:*:*:*:*:*", "matchCriteriaId": "26C40BAF-2C91-4069-A62E-1B1E60BA1619", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_tm221ce16r:-:*:*:*:*:*:*:*", "matchCriteriaId": "00715571-AC4B-4B1F-8E65-385B56F2004C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\x00\\x01\\x00\\x00\\x00\\x05\\x01\\x5a\\x00\\x03\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded." }, { "lang": "es", "value": "Los dispositivos Schneider Electric Modicon TM221CE16R 1.3.3.3 permiten a atacantes remotos descubrir la contrase\u00f1a de protecci\u00f3n de la aplicaci\u00f3n a trav\u00e9s de una solicitud \\x00\\x01\\x00\\x00\\x00\\x05\\x01\\x5a\\x00\\x03\\x00 al puerto Modbus (502/tcp). Posteriormente la aplicaci\u00f3n puede descargarse, modificarse y cargarse arbitrariamente." } ], "id": "CVE-2017-7575", "lastModified": "2025-04-20T01:37:25.860", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-04-06T21:59:00.337", "references": [ { "source": "cve@mitre.org", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/97523" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://os-s.net/advisories/OSS-2017-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/97523" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://os-s.net/advisories/OSS-2017-01.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…