fkie_cve-2017-7901
Vulnerability from fkie_nvd
Published
2017-06-30 03:29
Modified
2025-04-20 01:37
Summary
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E44D0CCE-EDA7-4DF2-B67B-C59DFAE7F888",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58E4AB51-E136-4AA3-AFF9-50F240489856",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6006CE1E-08EC-4AFC-8F35-73B24AA7F08D",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F52398D3-996E-4291-887F-6B8E0AF24AFF",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61603F24-7505-4A9E-BA9E-57C7B5A60A6E",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9558148B-3000-4D83-9AB0-380D7FBB0C9A",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C805AFD6-481C-4A32-9CE8-281F9B793263",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC9E1F42-4F17-4EA4-8D0F-30220F560A0E",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA98842B-9D09-4C37-AB34-4E9FA566BAD8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C8E3AF6-1017-4A18-99CA-854F1022ED66",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A093AA8B-7DB9-4373-AE8F-F8B879A4BE5E",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "25DA9309-964B-4C1C-8B95-9C1CD80DDC74",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D51D3F6-ABB3-4FFD-81D5-B3D3C29F0A46",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC05C3A1-1042-46AD-83D8-765AF4C9BCD9",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6218A006-1F60-4E29-85CC-7D1BCBD7C734",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B863572-CECF-47DF-AF6F-C25F88200DBE",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "59BEBB0E-8C6E-4663-9E0C-E755C2EF0041",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1303D987-4A44-4F33-992E-0C7E683EC7A9",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E7D8E09-D97D-45FF-9AD0-A9B0A846E600",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_a:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D9C64FB-A613-4940-86E6-95431B907159",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_b:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5C50D4A-EB32-4BE4-B9E6-D25494E2EF55",
              "versionEndIncluding": "16.000",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFF2EF59-F451-490D-A7AF-E66D11493948",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 un problema de Rango de Valor Predecible de Valores Anteriores en los controladores l\u00f3gicos programables MicroLogix 1100 1763-L16AWA, Series A y B, versi\u00f3n 16.00 y anteriores; 1763-L16BBB, Serie A y B, versi\u00f3n 16.00 y anteriores; 1763-L16BWA, Serie A y B, versi\u00f3n 16.00 y anteriores; y 1763-L16DWD, Series A y B, versi\u00f3n 16.00 y anteriores de Allen-Bradley en Rockwell Automation y en controladores l\u00f3gicos programables MicroLogix 1400 1766-L32AWA, Series A y B, versi\u00f3n 16.00 y anteriores; 1766-L32BWA, Serie A y B, versi\u00f3n 16.00 y anteriores; 1766-L32BWAA, Serie A y B, versi\u00f3n 16.00 y anteriores; 1766-L32BXB, Serie A y B, versi\u00f3n 16.00 y anteriores; 1766-L32BXBA, Serie A y B, versi\u00f3n 16.00 y anteriores; y 1766-L32AWAA, Series A y B, versi\u00f3n 16.00 y anteriores de Allen-Bradley en Rockwell Automation. Se generan n\u00fameros de secuencia inicial TCP de aleatoriedad insuficientemente, lo que puede permitir a un atacante predecir los n\u00fameros de los valores anteriores. Esto puede permitir a un atacante suplantar o interrumpir las conexiones TCP, resultando en una denegaci\u00f3n de servicio para el dispositivo de destino."
    }
  ],
  "id": "CVE-2017-7901",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": true,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 8.5,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-06-30T03:29:00.797",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://www.securitytracker.com/id/1038546"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securitytracker.com/id/1038546"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-343"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-330"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…