fkie_cve-2018-7824
Vulnerability from fkie_nvd
Published
2019-05-22 20:29
Modified
2024-11-21 04:12
Severity ?
Summary
An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files.
References
▶ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/ | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/ | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | modbus_serial_driver | * | |
microsoft | windows | - | |
schneider-electric | modbus_serial_driver | * | |
microsoft | windows | - | |
schneider-electric | driver_suite | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7535403-6248-47E9-A381-65680E269E6B", "versionEndIncluding": "3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:x64:*", "matchCriteriaId": "82132539-3C34-4B63-BE2A-F51077D8BC5A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:*:*", "matchCriteriaId": "203AD4F6-98F6-421B-8037-547FD7882228", "versionEndIncluding": "2.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:x86:*", "matchCriteriaId": "60366048-32FE-4081-A852-04319FD7A52C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:driver_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FE70BFB-F058-4D31-9558-B96DC0B8EFAB", "versionEndIncluding": "14.12", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files." }, { "lang": "es", "value": "Existe una vulnerabilidad de tipo referencias a recurso controlado externamente (CWE-610) en Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 y anterior, para Windows 32-bit OS:V2.17 IE 27 y anterior, y como parte del Driver Suite versi\u00f3n:V14.12 y anterior), que podr\u00eda permitir el acceso de escritura a los archivos del sistema disponibles solo para usuarios con privilegio SYSTEM u otros archivos de usuarios importantes." } ], "id": "CVE-2018-7824", "lastModified": "2024-11-21T04:12:47.890", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 6.8, "confidentialityImpact": "NONE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-05-22T20:29:01.150", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-610" } ], "source": "cybersecurity@se.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-610" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…