fkie_cve-2019-6838
Vulnerability from fkie_nvd
Published
2019-09-17 20:15
Modified
2024-11-21 04:47
Severity ?
Summary
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to delete a critical file.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:meg6501-0001_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "716CA99C-BB90-422B-9EAD-A066D48DE1E8", "versionEndExcluding": "1.3.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:meg6501-0001:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB83620B-3DE0-405A-92F7-99E1B2150E75", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:meg6501-0002_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D2468D0-D50D-4843-8620-CAD0F40E9329", "versionEndExcluding": "1.3.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:meg6501-0002:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC12A2AA-C006-4606-981A-FE54C1EA3B3F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:meg6260-0410_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB404224-29BF-4440-963C-0734A51CE6D1", "versionEndExcluding": "1.3.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:meg6260-0410:-:*:*:*:*:*:*:*", "matchCriteriaId": "0936523A-B9CB-451E-BF5E-9E7020DA96A2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:meg6260-0415_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C17C8F6-8C97-43D5-8ECE-7D9204F3C75D", "versionEndExcluding": "1.3.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:meg6260-0415:-:*:*:*:*:*:*:*", "matchCriteriaId": "F93C8296-5845-498A-964A-D650F45B27B6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to delete a critical file." }, { "lang": "es", "value": "Un Control de Acceso Inapropiado: Se presenta una vulnerabilidad CWE-863 en U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10 , MEG6260-0415 - U.motion KNX Server Plus, Touch 15), lo que podr\u00eda permitir a un usuario con pocos privilegios eliminar un archivo cr\u00edtico" } ], "id": "CVE-2019-6838", "lastModified": "2024-11-21T04:47:15.217", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-09-17T20:15:12.717", "references": [ { "source": "cybersecurity@se.com", "url": "https://www.se.com/ww/en/download/document/SEVD-2019-253-01/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.se.com/ww/en/download/document/SEVD-2019-253-01/" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-863" } ], "source": "cybersecurity@se.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…