fkie_cve-2020-27267
Vulnerability from fkie_nvd
Published
2021-01-14 00:15
Modified
2024-11-21 05:20
Severity ?
Summary
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
ge | industrial_gateway_server | 7.66 | |
ge | industrial_gateway_server | 7.68.804 | |
ptc | kepware_kepserverex | 6.0 | |
ptc | kepware_kepserverex | 6.9 | |
ptc | opc-aggregator | - | |
ptc | thingworx_industrial_connectivity | - | |
ptc | thingworx_kepware_server | 6.8 | |
ptc | thingworx_kepware_server | 6.9 | |
rockwellautomation | kepserver_enterprise | 6.6.504.0 | |
rockwellautomation | kepserver_enterprise | 6.9.572.0 | |
softwaretoolbox | top_server | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.66:*:*:*:*:*:*:*", "matchCriteriaId": "E5AEAC75-5E69-4C49-8D57-35401400C9D2", "vulnerable": true }, { "criteria": "cpe:2.3:a:ge:industrial_gateway_server:7.68.804:*:*:*:*:*:*:*", "matchCriteriaId": "906B1D62-7656-457E-B528-B0407C9D0BA4", "vulnerable": true }, { "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.0:*:*:*:*:*:*:*", "matchCriteriaId": "6994DBB6-BA65-4E47-B0E4-42310120FC04", "vulnerable": true }, { "criteria": "cpe:2.3:a:ptc:kepware_kepserverex:6.9:*:*:*:*:*:*:*", "matchCriteriaId": "FC1720A3-85F1-4A85-B226-1CCBB34FCAAC", "vulnerable": true }, { "criteria": "cpe:2.3:a:ptc:opc-aggregator:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8F46490-09F7-488A-B1EB-2286BFA0F882", "vulnerable": true }, { "criteria": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*", "matchCriteriaId": "D01A814D-8F2B-4B88-A66B-F2A2C293A6AB", "vulnerable": true }, { "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.8:*:*:*:*:*:*:*", "matchCriteriaId": "2DE510A4-1D91-447E-BF61-6CDFDFF82796", "vulnerable": true }, { "criteria": "cpe:2.3:a:ptc:thingworx_kepware_server:6.9:*:*:*:*:*:*:*", "matchCriteriaId": "2F16FBD0-8841-4E42-8FE6-796F7B4E5C16", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.6.504.0:*:*:*:*:*:*:*", "matchCriteriaId": "6FFA2B21-E36C-41CE-B633-B831C6D42962", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.9.572.0:*:*:*:*:*:*:*", "matchCriteriaId": "BACC2F09-9EC8-420A-B499-BF7CD737A473", "vulnerable": true }, { "criteria": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "95B527BB-A27F-4080-8BBB-3FCA2408B7AE", "versionEndIncluding": "6.9", "versionStartIncluding": "6.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data." }, { "lang": "es", "value": "KEPServerEX versiones v6.0 hasta v6.9, ThingWorx Kepware Server versiones v6.8 y v6.9, ThingWorx Industrial Connectivity (todas las versiones), OPC-Aggregator (todas las versiones), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server versiones v7.68.804 y v7.66, y Software Toolbox TOP Server, todas las versiones 6.x, son vulnerables a un desbordamiento del b\u00fafer en la regi\u00f3n heap de la memoria.\u0026#xa0;Abrir un mensaje OPC UA espec\u00edficamente dise\u00f1ado podr\u00eda permitir a un atacante bloquear el servidor y potencialmente filtrar datos" } ], "id": "CVE-2020-27267", "lastModified": "2024-11-21T05:20:58.280", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-01-14T00:15:13.510", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-416" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…