fkie_cve-2020-6790
Vulnerability from fkie_nvd
Published
2021-03-25 16:15
Modified
2024-11-21 05:36
Summary
Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from.
Impacted products
Vendor Product Version
bosch video_streaming_gateway *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78EDF599-23DF-434A-B1EF-D26A948C6481",
              "versionEndIncluding": "6.45.10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from."
    },
    {
      "lang": "es",
      "value": "Llamar un ejecutable mediante un Elemento de Ruta de B\u00fasqueda no Controlada en el instalador de Bosch Video Streaming Gateway versiones hasta 6.45.10 incluy\u00e9ndola, permite a un atacante ejecutar c\u00f3digo arbitrario en el sistema de la v\u00edctima.\u0026#xa0;Un requisito previo es que la v\u00edctima sea enga\u00f1ada para colocar un exe malicioso en el mismo directorio desde el que se inicia el instalador"
    }
  ],
  "id": "CVE-2020-6790",
  "lastModified": "2024-11-21T05:36:11.420",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.9,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.4,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "psirt@bosch.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-03-25T16:15:13.867",
  "references": [
    {
      "source": "psirt@bosch.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
    }
  ],
  "sourceIdentifier": "psirt@bosch.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ],
      "source": "psirt@bosch.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…