fkie_cve-2021-23862
Vulnerability from fkie_nvd
Published
2021-12-08 22:15
Modified
2024-11-21 05:51
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in system context. This issue also affects installations of the VRM, DIVAR IP, BVMS with VRM installed, the VIDEOJET decoder (VJD-7513 and VJD-8000).
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "0B9DD276-15C0-4942-8899-553F7C190320", "versionEndIncluding": "9.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "989D5F9A-D223-4070-82AE-FA79E8B2572C", "versionEndExcluding": "10.0.2", "versionStartIncluding": "10.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:bosch_video_management_system:10.1:*:*:*:*:*:*:*", "matchCriteriaId": "57FA3EF2-6A7C-46FD-A758-92045A3A2DEE", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:bosch_video_management_system:11.0:*:*:*:*:*:*:*", "matchCriteriaId": "1FF22168-E2A2-47B8-B9BC-104FF1CFDF30", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "D54B21E5-8C3E-423F-8E49-9F05B41D540B", "versionEndIncluding": "3.81", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "31D1E38A-C0F8-421B-B837-3D2FBD132A18", "versionEndIncluding": "3.82.0057", "versionStartIncluding": "3.82", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "7171D63A-3A1A-4235-9317-009D7C85A93C", "versionEndIncluding": "3.83.0021", "versionStartIncluding": "3.83", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "31572EBA-C58A-46E8-88EA-ADE04578E039", "versionEndIncluding": "4.00.0070", "versionStartIncluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_5000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "E2C1615D-2E5F-4D49-B937-05C81AB5414C", "vulnerable": false }, { "criteria": "cpe:2.3:o:bosch:divar_ip_7000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7CCD42BE-E4B7-43FC-95FB-C97704E5C268", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:videojet_decoder_7513_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC7D70DA-4C3A-4B37-B3E6-266B232FA117", "versionEndIncluding": "10.22.0038", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:videojet_decoder_7513:-:*:*:*:*:*:*:*", "matchCriteriaId": "A96A7B0B-4C65-412E-8AB0-BD6098548598", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:videojet_decoder_8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C28B95FD-5932-4255-9AFE-85229C37C87D", "versionEndIncluding": "10.01.0036", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:videojet_decoder_8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "028FEDCC-7774-4D17-B017-653365BE0297", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in system context. This issue also affects installations of the VRM, DIVAR IP, BVMS with VRM installed, the VIDEOJET decoder (VJD-7513 and VJD-8000)." }, { "lang": "es", "value": "Un paquete de configuraci\u00f3n dise\u00f1ado enviado por un usuario administrativo autenticado puede ser usado para ejecutar comandos arbitrarios en el contexto del sistema. Este problema tambi\u00e9n afecta a las instalaciones de VRM, DIVAR IP, BVMS con VRM instalado, el decodificador VIDEOJET (VJD-7513 y VJD-8000)" } ], "id": "CVE-2021-23862", "lastModified": "2024-11-21T05:51:58.453", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "psirt@bosch.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-08T22:15:08.607", "references": [ { "source": "psirt@bosch.com", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-043434-bt.html" } ], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "psirt@bosch.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…