fkie_cve-2021-25660
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:55
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
Impacted products
Vendor Product Version
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_7\" -
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 16
siemens simatic_hmi_comfort_outdoor_panels_15\" -
siemens simatic_hmi_comfort_panels_4\"_firmware *
siemens simatic_hmi_comfort_panels_4\"_firmware 16
siemens simatic_hmi_comfort_panels_4\"_firmware 16
siemens simatic_hmi_comfort_panels_4\"_firmware 16
siemens simatic_hmi_comfort_panels_4\"_firmware 16
siemens simatic_hmi_comfort_panels_4\" -
siemens simatic_hmi_comfort_panels_22\"_firmware *
siemens simatic_hmi_comfort_panels_22\"_firmware 16
siemens simatic_hmi_comfort_panels_22\"_firmware 16
siemens simatic_hmi_comfort_panels_22\"_firmware 16
siemens simatic_hmi_comfort_panels_22\"_firmware 16
siemens simatic_hmi_comfort_panels_22\" -
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp400f -
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700 -
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp700f -
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900 -
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 16
siemens simatic_hmi_ktp_mobile_panels_ktp900f -
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_runtime_advanced 16
siemens simatic_wincc_runtime_advanced 16
siemens simatic_wincc_runtime_advanced 16
siemens simatic_wincc_runtime_advanced 16
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_7\" -
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_15\" -
siemens simatic_hmi_comfort_panels_4\"_firmware *
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\"_firmware 15.1
siemens simatic_hmi_comfort_panels_4\" -
siemens simatic_hmi_comfort_panels_22\"_firmware *
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\"_firmware 15.1
siemens simatic_hmi_comfort_panels_22\" -
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f -
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700 -
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f -
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900 -
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f -
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*",
              "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*",
              "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*",
              "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" y 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4). SmartVNC presenta una vulnerabilidad de acceso a la memoria fuera de l\u00edmites que podr\u00eda ser desencadenada en el lado del servidor al enviar datos desde el cliente, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio"
    }
  ],
  "id": "CVE-2021-25660",
  "lastModified": "2024-11-21T05:55:14.307",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-12T14:15:11.253",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-788"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…