Summary
Under some circumstances an Insufficiently Protected Credentials vulnerability in Johnson Controls Metasys ADS/ADX/OAS 10 versions prior to 10.1.6 and 11 versions prior to 11.0.3 allows API calls to expose credentials in plain text.
References
▶ | URL | Tags | |
---|---|---|---|
productsecurity@jci.com | https://www.cisa.gov/uscert/ics/advisories/icsa-23-012-06 | Third Party Advisory, US Government Resource | |
productsecurity@jci.com | https://www.johnsoncontrols.com/cyber-solutions/security-advisories | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-23-012-06 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.johnsoncontrols.com/cyber-solutions/security-advisories | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:johnsoncontrols:metasys_application_and_data_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD7580CF-9B2D-441F-9F87-2D3AA0972F65", "versionEndExcluding": "10.1.6", "versionStartIncluding": "10.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:johnsoncontrols:metasys_application_and_data_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "262BBB40-E1BB-4C89-B92F-0B43FBF0B64C", "versionEndExcluding": "11.0.3", "versionStartIncluding": "11.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:johnsoncontrols:metasys_extended_application_and_data_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C3A978D-692C-4023-8A2E-B1F28B57763B", "versionEndExcluding": "10.1.6", "versionStartIncluding": "10.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:johnsoncontrols:metasys_extended_application_and_data_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9CD5BAD-C152-4740-B289-206777A4B918", "versionEndExcluding": "11.0.3", "versionStartIncluding": "11.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:johnsoncontrols:metasys_open_application_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA185C2A-D5DE-4346-A409-0C457D72848D", "versionEndExcluding": "10.1.6", "versionStartIncluding": "10.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:johnsoncontrols:metasys_open_application_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5A5399D-16B3-4C4A-ADB2-791BD1449B0F", "versionEndExcluding": "11.0.3", "versionStartIncluding": "11.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Under some circumstances an Insufficiently Protected Credentials vulnerability in Johnson Controls Metasys ADS/ADX/OAS 10 versions prior to 10.1.6 and 11 versions prior to 11.0.3 allows API calls to expose credentials in plain text." }, { "lang": "es", "value": "En algunas circunstancias, una vulnerabilidad de credenciales insuficientemente protegidas en Johnson Controls Metasys ADS/ADX/OAS versiones 10 anteriores a 10.1.6 y 11 versiones anteriores a 11.0.3 permite que las llamadas API expongan credenciales en texto plano." } ], "id": "CVE-2021-36204", "lastModified": "2024-11-21T06:13:18.790", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productsecurity@jci.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-01-13T21:15:15.360", "references": [ { "source": "productsecurity@jci.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-012-06" }, { "source": "productsecurity@jci.com", "tags": [ "Vendor Advisory" ], "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-012-06" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories" } ], "sourceIdentifier": "productsecurity@jci.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "productsecurity@jci.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…