fkie_cve-2022-24655
Vulnerability from fkie_nvd
Published
2022-03-18 11:15
Modified
2024-11-21 06:50
Summary
A stack overflow vulnerability exists in the upnpd service in Netgear EX6100v1 201.0.2.28, CAX80 2.1.2.6, and DC112A 1.0.0.62, which may lead to the execution of arbitrary code without authentication.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6100_firmware:201.0.2.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "37A39F3F-B85E-4BB3-BA63-5CB0602F5550",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB84CD03-765C-4D4F-A176-364F8E72A4E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A858641D-FD51-4A0C-B09B-A72DA47B6961",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3186CC67-B567-4A0C-BD2C-0433716FBD1B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cax80_firmware:2.1.2.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "28C36F9E-A167-4D47-9146-BE00629E2549",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "673A83EA-E359-4629-8B20-5382C15260B2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:dc112a_firmware:1.0.0.62:*:*:*:*:*:*:*",
              "matchCriteriaId": "8421345C-55A1-49B3-9A2F-B9D231BBBE4C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A stack overflow vulnerability exists in the upnpd service in Netgear EX6100v1 201.0.2.28, CAX80 2.1.2.6, and DC112A 1.0.0.62, which may lead to the execution of arbitrary code without authentication."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de desbordamiento de pila en el servicio upnpd de Netgear EX6100v1 versi\u00f3n 201.0.2.28, CAX80 versi\u00f3n 2.1.2.6 y DC112A versi\u00f3n 1.0.0.62, que puede conllevar a una ejecuci\u00f3n de c\u00f3digo arbitrario sin autenticaci\u00f3n"
    }
  ],
  "id": "CVE-2022-24655",
  "lastModified": "2024-11-21T06:50:48.120",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T11:15:08.010",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://github.com/doudoudedi/Netgear_product_stack_overflow/blob/main/NETGEAR%20EX%20series%20upnpd%20stack_overflow.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064615/Security-Advisory-for-Pre-Authentication-Command-Injection-on-EX6100v1-and-Pre-Authentication-Stack-Overflow-on-Multiple-Products-PSV-2021-0282-PSV-2021-0288"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.netgear.com/about/security/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://github.com/doudoudedi/Netgear_product_stack_overflow/blob/main/NETGEAR%20EX%20series%20upnpd%20stack_overflow.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064615/Security-Advisory-for-Pre-Authentication-Command-Injection-on-EX6100v1-and-Pre-Authentication-Stack-Overflow-on-Multiple-Products-PSV-2021-0282-PSV-2021-0288"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.netgear.com/about/security/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…