Summary
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
abb | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E218D81E-9E3B-47A4-829E-8D79CC6C017A", "versionEndExcluding": "12.2.12.0", "versionStartIncluding": "12.2.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5651891D-EAD1-4E41-82E9-DFE762A3C35D", "versionEndExcluding": "12.0.14.0", "versionStartIncluding": "12.0.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "229DCAE7-8362-4C5F-B708-9B130123DAAC", "versionEndExcluding": "12.4.12.0", "versionStartIncluding": "12.4.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BF67F27-4854-47BC-A0E1-BB3A918C9F36", "versionEndExcluding": "12.6.8.0", "versionStartIncluding": "12.6.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D0C47FBB-38D1-46D5-8381-3AF69EF78A44", "versionEndExcluding": "12.7.4.0", "versionStartIncluding": "12.7.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4867D76C-DB3D-4E48-8BB1-FE8336F4A979", "versionEndExcluding": "13.2.5.0", "versionStartIncluding": "13.2.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE94252D-03EE-451B-8322-B4DBC790C6E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function." }, { "lang": "es", "value": "Una vulnerabilidad en el COMPONENTE HCI Modbus TCP del firmware de la CMU de la serie RTU500 de Hitachi Energy, causada por un error de comprobaci\u00f3n en la informaci\u00f3n de longitud que se transmite en el encabezado MBAP, permite a un ATACANTE reiniciar el dispositivo mediante el env\u00edo de un mensaje especialmente dise\u00f1ado. Este problema afecta a: Hitachi Energy RTU500 series CMU Firmware versiones 12.0.*; 12.2.*; 12.4.*; 12.6.*; 12.7.*; 13.2.*" } ], "id": "CVE-2022-28613", "lastModified": "2024-11-21T06:57:34.920", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-05-02T19:15:09.200", "references": [ { "source": "cybersecurity@hitachienergy.com", "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000103\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000103\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-1284" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-1284" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…