fkie_cve-2022-34819
Vulnerability from fkie_nvd
Published
2022-07-12 10:15
Modified
2024-11-21 07:10
Summary
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1674851A-D8DC-47C5-9D63-2F1082CE0366",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFC6ACFD-8893-4EA3-976B-FAAF7240C5DB",
              "versionEndExcluding": "3.0.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78127221-D455-4145-9B84-A598A284D591",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23C55242-F638-415E-B683-EE1484770105",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07505420-ADE4-4409-AFCC-45BCBC995543",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C624BBC7-D8C5-4C2F-B56B-D59D55F013F8",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "43CDCCE3-B8C0-44D4-A8A0-25C49A4EA240",
              "versionEndExcluding": "3.0.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D7AB0D5-FD3E-416A-975B-D212B3350433",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE EU (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE US (Todas las versiones anteriores a V3. 3.46), SIMATIC CP 1243-8 IRC (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1542SP-1 IRC (Todas las versiones posteriores o iguales a V2.0), SIMATIC CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIMATIC CP 1543SP-1 (Todas las versiones posteriores o iguales a V2. 0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (Todas las versiones posteriores o iguales a V2. 0), SIPLUS NET CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIPLUS NET CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIPLUS S7-1200 CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (Todas las versiones anteriores a V3.3.46). La aplicaci\u00f3n carece de una validaci\u00f3n adecuada de los datos suministrados por el usuario al analizar mensajes espec\u00edficos. Esto podr\u00eda dar lugar a un desbordamiento del b\u00fafer basado en la pila. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del dispositivo"
    }
  ],
  "id": "CVE-2022-34819",
  "lastModified": "2024-11-21T07:10:14.917",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-07-12T10:15:12.293",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…