fkie_cve-2022-35868
Vulnerability from fkie_nvd
Published
2023-02-14 11:15
Modified
2024-11-21 07:11
Severity ?
6.7 (Medium) - CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in TIA Multiuser Server V14 (All versions), TIA Multiuser Server V15 (All versions < V15.1 Update 8), TIA Project-Server (All versions < V1.1), TIA Project-Server V16 (All versions), TIA Project-Server V17 (All versions < V17 Update 6). Affected applications contain an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to start the service from an attacker controlled path.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | tia_multiuser_server | 14 | |
siemens | tia_multiuser_server | 15 | |
siemens | tia_multiuser_server | 15.1 | |
siemens | tia_multiuser_server | 16 | |
siemens | tia_project-server | 1.0 | |
siemens | tia_project-server | 17 | |
siemens | tia_project-server | 17 | |
siemens | tia_project-server | 17 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:tia_multiuser_server:14:*:*:*:*:*:*:*", "matchCriteriaId": "51295D3A-D80A-4EFF-A373-C908A48210DB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_multiuser_server:15:*:*:*:*:*:*:*", "matchCriteriaId": "11218F6A-21F0-4F5F-845D-E24EBBFCA311", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_multiuser_server:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "CD0DDDC9-9781-401E-885B-816095F8944E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_multiuser_server:16:*:*:*:*:*:*:*", "matchCriteriaId": "24838AA8-AEA0-4E0F-BA2A-62C7021D63C9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_project-server:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "E00DE29E-248E-4F4E-A265-FA677894AD5F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_project-server:17:-:*:*:*:*:*:*", "matchCriteriaId": "ED59034F-53F8-43F7-B2A8-749A22DCFC13", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_project-server:17:update1:*:*:*:*:*:*", "matchCriteriaId": "F551BE2C-A958-482D-BD6C-D2970CCCCBBE", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_project-server:17:update4:*:*:*:*:*:*", "matchCriteriaId": "449FE07D-00D9-44C6-8DD3-CAC06C5F8FBC", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in TIA Multiuser Server V14 (All versions), TIA Multiuser Server V15 (All versions \u003c V15.1 Update 8), TIA Project-Server (All versions \u003c V1.1), TIA Project-Server V16 (All versions), TIA Project-Server V17 (All versions \u003c V17 Update 6). Affected applications contain an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to start the service from an attacker controlled path." } ], "id": "CVE-2022-35868", "lastModified": "2024-11-21T07:11:50.580", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-02-14T11:15:12.847", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-640968.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640968.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640968.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-426" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-426" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…