fkie_cve-2022-3752
Vulnerability from fkie_nvd
Published
2022-12-19 23:15
Modified
2024-11-21 07:20
Severity ?
8.6 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic
loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload
the user project file to bring the device back online and continue normal operation.
References
▶ | URL | Tags | |
---|---|---|---|
PSIRT@rockwellautomation.com | https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137664 | Permissions Required, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137664 | Permissions Required, Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A3BB8945-AC46-463C-A7D9-15584AD0FA68", "versionStartIncluding": "32.011", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*", "matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5580_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EDD27C92-CC9B-4780-B7AC-8ECBE1FF7C77", "versionStartIncluding": "31.011", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5580:-:*:*:*:*:*:*:*", "matchCriteriaId": "CEA62D6E-168F-4EEC-9E90-C679273C1CDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "25846D71-4F46-4C50-BB76-5D692DE9ACFE", "versionStartIncluding": "32.011", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*", "matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E187CC9F-3BFC-4AE3-A4E5-477416A16E24", "versionStartIncluding": "31.011", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*", "matchCriteriaId": "62414E65-73C7-4172-B7BF-F40A66AFBB90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65D5D8EB-6A19-4849-988D-C3F65071B05F", "versionStartIncluding": "31.011", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*", "matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic \nloading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload \nthe user project file to bring the device back online and continue normal operation.\n\n\n" }, { "lang": "es", "value": "Un usuario no autorizado podr\u00eda utilizar una secuencia especialmente manipulada de mensajes Ethernet/IP, combinada con una gran carga de tr\u00e1fico, para provocar una condici\u00f3n de Denegaci\u00f3n de Servicio (DoS) en los controladores Logix de Rockwell Automation, lo que provocar\u00eda una falla importante no recuperable. Si el dispositivo de destino deja de estar disponible, el usuario tendr\u00eda que borrar la falla y volver a descargar el archivo de proyecto del usuario para volver a poner el dispositivo en l\u00ednea y continuar con el funcionamiento normal." } ], "id": "CVE-2022-3752", "lastModified": "2024-11-21T07:20:10.707", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 4.0, "source": "PSIRT@rockwellautomation.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-12-19T23:15:10.660", "references": [ { "source": "PSIRT@rockwellautomation.com", "tags": [ "Permissions Required", "Vendor Advisory" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137664" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Vendor Advisory" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137664" } ], "sourceIdentifier": "PSIRT@rockwellautomation.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "PSIRT@rockwellautomation.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…