fkie_cve-2022-38377
Vulnerability from fkie_nvd
Published
2022-11-25 16:15
Modified
2024-11-21 07:16
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N
Summary
An improper access control vulnerability [CWE-284] in FortiManager 7.2.0, 7.0.0 through 7.0.3, 6.4.0 through 6.4.7, 6.2.0 through 6.2.9, 6.0.0 through 6.0.11 and FortiAnalyzer 7.2.0, 7.0.0 through 7.0.3, 6.4.0 through 6.4.8, 6.2.0 through 6.2.10, 6.0.0 through 6.0.12 may allow a remote and authenticated admin user assigned to a specific ADOM to access other ADOMs information such as device information and dashboard information.
References
▶ | URL | Tags | |
---|---|---|---|
psirt@fortinet.com | https://fortiguard.com/psirt/FG-IR-20-143 | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://fortiguard.com/psirt/FG-IR-20-143 | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
fortinet | fortianalyzer | * | |
fortinet | fortianalyzer | * | |
fortinet | fortianalyzer | * | |
fortinet | fortianalyzer | * | |
fortinet | fortianalyzer | 7.2.0 | |
fortinet | fortimanager | * | |
fortinet | fortimanager | * | |
fortinet | fortimanager | * | |
fortinet | fortimanager | * | |
fortinet | fortimanager | 7.2.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*", "matchCriteriaId": "2318A6AC-AA3E-4604-968C-35A46E79FCB8", "versionEndIncluding": "6.0.12", "versionStartIncluding": "6.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*", "matchCriteriaId": "5E816164-8C08-4BF7-863B-112076AB6AE2", "versionEndIncluding": "6.2.10", "versionStartIncluding": "6.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*", "matchCriteriaId": "19769C95-B563-476D-A4B3-6C317294F1E9", "versionEndIncluding": "6.4.8", "versionStartIncluding": "6.4.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*", "matchCriteriaId": "42D096D2-1FCB-43A6-8CF3-3226F631BAC4", "versionEndIncluding": "7.0.3", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:7.2.0:*:*:*:*:*:*:*", "matchCriteriaId": "319D2F9D-E1E5-49C7-8ABD-0A64D7B05D58", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD729EF3-1665-4CE7-9FDD-450D5F79A2B9", "versionEndIncluding": "6.0.11", "versionStartIncluding": "6.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D79F4BE-B6BB-414A-A132-D3650B2B5B4F", "versionEndIncluding": "6.2.9", "versionStartIncluding": "6.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "matchCriteriaId": "105F23CF-6375-402E-A2ED-9827510196EA", "versionEndIncluding": "6.4.7", "versionStartIncluding": "6.4.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA4F8D67-139F-4524-88D4-B32A1580BFBE", "versionEndIncluding": "7.0.3", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:7.2.0:*:*:*:*:*:*:*", "matchCriteriaId": "407755AA-0C23-4C5B-88A2-8BC12A3D268D", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An improper access control vulnerability [CWE-284] in FortiManager 7.2.0, 7.0.0 through 7.0.3, 6.4.0 through 6.4.7, 6.2.0 through 6.2.9, 6.0.0 through 6.0.11 and FortiAnalyzer 7.2.0, 7.0.0 through 7.0.3, 6.4.0 through 6.4.8, 6.2.0 through 6.2.10, 6.0.0 through 6.0.12 may allow a remote and authenticated admin user assigned to a specific ADOM to access other ADOMs information such as device information and dashboard information." }, { "lang": "es", "value": "Una vulnerabilidad de control de acceso inadecuado [CWE-284] en FortiManager 7.2.0, 7.0.0 a 7.0.3, 6.4.0 a 6.4.7, 6.2.0 a 6.2.9, 6.0.0 a 6.0.11 y FortiAnalyzer 7.2 .0, 7.0.0 a 7.0.3, 6.4.0 a 6.4.8, 6.2.0 a 6.2.10, 6.0.0 a 6.0.12 pueden permitir que un usuario administrador remoto y autenticado asignado a un ADOM espec\u00edfico acceda a otros ADOM de informaci\u00f3n, como informaci\u00f3n del dispositivo e informaci\u00f3n del panel." } ], "id": "CVE-2022-38377", "lastModified": "2024-11-21T07:16:21.223", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "psirt@fortinet.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-11-25T16:15:10.747", "references": [ { "source": "psirt@fortinet.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://fortiguard.com/psirt/FG-IR-20-143" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://fortiguard.com/psirt/FG-IR-20-143" } ], "sourceIdentifier": "psirt@fortinet.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-284" } ], "source": "psirt@fortinet.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…