Summary
Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are "16" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially crafted packets to any UDP port when GC-ENET-COM is configured as a Modbus TCP Server. The communication resumes only when the power of the main unit is turned off and on or when the GC-ENET-COM is hot-swapped from the main unit.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
mitsubishielectric | gc-enet-com_firmware | - | |
mitsubishielectric | gc-enet-com | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:gc-enet-com_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A0AA732-9C55-45CA-A049-5D8BC40926A5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:gc-enet-com:-:*:*:*:*:*:*:*", "matchCriteriaId": "FB5D1352-A15E-43A5-9CF7-374E4DA7A080", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are \"16\" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially crafted packets to any UDP port when GC-ENET-COM is configured as a Modbus TCP Server. The communication resumes only when the power of the main unit is turned off and on or when the GC-ENET-COM is hot-swapped from the main unit.\n" } ], "id": "CVE-2023-1285", "lastModified": "2024-11-21T07:38:49.580", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-04-14T03:15:07.003", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Vendor Advisory" ], "url": "https://mitsubishielectric.in/fa/cnc-pdf/DoS_in_Ethernet_Communication_Extension_Unit_GC_ENET_COM_of_GOC35_Series.pdf" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-15" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://mitsubishielectric.in/fa/cnc-pdf/DoS_in_Ethernet_Communication_Extension_Unit_GC_ENET_COM_of_GOC35_Series.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-15" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-364" } ], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-362" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…