fkie_cve-2023-32474
Vulnerability from fkie_nvd
Published
2024-02-06 08:15
Modified
2024-11-21 08:03
Severity ?
6.6 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:H
6.6 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:H
6.6 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:H
Summary
Dell Display Manager application, version 2.1.1.17 and prior, contain an insecure operation on windows junction/mount point. A local malicious user could potentially exploit this vulnerability during installation leading to arbitrary folder or file deletion
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dell | display_manager | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:dell:display_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "BFE32F01-E2FB-439E-8E2D-2A5E59FBC76B", "versionEndExcluding": "2.1.1.21", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nDell Display Manager application, version 2.1.1.17 and prior, contain an insecure operation on windows junction/mount point. A local malicious user could potentially exploit this vulnerability during installation leading to arbitrary folder or file deletion\n\n" }, { "lang": "es", "value": "La aplicaci\u00f3n Dell Display Manager, versi\u00f3n 2.1.1.17 y anteriores, contiene una operaci\u00f3n no segura en el punto de uni\u00f3n/montaje de Windows. Un usuario malintencionado local podr\u00eda explotar esta vulnerabilidad durante la instalaci\u00f3n, lo que provocar\u00eda la eliminaci\u00f3n de archivos o carpetas arbitrarias." } ], "id": "CVE-2023-32474", "lastModified": "2024-11-21T08:03:25.767", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 5.2, "source": "security_alert@emc.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-02-06T08:15:50.647", "references": [ { "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000215216/dsa-2023-182-dell" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000215216/dsa-2023-182-dell" } ], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-1386" } ], "source": "security_alert@emc.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-59" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.