fkie_cve-2023-39464
Vulnerability from fkie_nvd
Published
2024-05-03 03:15
Modified
2025-06-17 21:03
Summary
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
Impacted products
Vendor Product Version
trianglemicroworks scada_data_gateway 5.1.3.20324



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538."
    },
    {
      "lang": "es",
      "value": "Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo en ruta de b\u00fasqueda sin comillas. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Aunque se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticaci\u00f3n existente. La falla espec\u00edfica existe en la configuraci\u00f3n del servicio GTWWebMonitorService. La ruta al ejecutable del servicio contiene espacios que no est\u00e1n entre comillas. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo arbitrario en el contexto de la ra\u00edz. Era ZDI-CAN-20538."
    }
  ],
  "id": "CVE-2023-39464",
  "lastModified": "2025-06-17T21:03:26.297",
  "metrics": {
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-03T03:15:11.870",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Release Notes"
      ],
      "url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
    },
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1032/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1032/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-428"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…